Wuhan Raycus Fiber Laser Technologies Co., Ltd.
User Guide of RFL-C3300W~RFL-C15000W
7
Output
Power
Unstability
±1.5%
Nominal
Output
Power;
Duration:
5hrs;
Ambient
Temp.: 25
Modulation
Frequency(
Hz)
505k
502k
Nominal
Output
Power
Red Guide
Laser
Power(mW)
0.51
/
Fiber output
Types
HQBH
QD
/
Beam
Quality
(BPP,
mm•mrad)
< 4.5
< 5
Nominal
Output
Power
Divergence
angle
rad
0.1
Nominal
Output
Power
Fiber core
diameter
(μm)
100
customizable
Delivery
Cable
Length(m)
20
30
20
customizable
Electrical characteristics
Operating
Voltage
Three-phase four-wire system AC340V~AC420V
50/60Hz
Include PE
/
Maximum
power
Consumptio
n (kW)
9.5
12.5
18.5
24.5
30.5
36.5
45.5
/
Way to
control
Serial communication / AD
/
Other characteristics
/
Dimension
mm
670×990×1160
900×960×1160
960×1020×1600
960×1220
×1600
Includes
casters and
rings,
without
warning
lights