Important:
Beawarethatthesuitablefuseratingforthethermalbreak
erorfuseisdependentonthenumber
ofdevicesyouareconnecting.
P
owercableextension
Ifyouneedtoextendthelengthofthepowercablesuppliedwithyourproduct,ensureyouobserve
thefollowingadvice:
Thepowercableforeachunitinyoursystemshouldberunasaseparate,singlelengthof2-wire
cablefromtheunittothevessel'sbatteryordistributionpanel.
Forpowercableextensions,itisrecommendedthataminimumwiregaugeof16AWG(1.31mm
2
).
Forcablerunslongerthan15meters,youmayneedtoconsiderathickerwiregauge(e.g.14AWG
(2.08mm
2
),or12AWG(3.31mm
2
)).
Animportantrequirementforalllengthsofpowercable(includinganyextension)istoensure
thatthereisacontinuousminimumvoltageof10.8Vattheproduct’spowerconnector,witha
fullyflatbatteryat11V.
Important:Beawarethatsomeproductsinyoursystem(suchassonarmodules)cancreatevoltage
peak satcertaintimes,whichmayimpactthevoltageavailabletootherproductsduringthepeaks.
Grounding
Ensurethatyouobservetheseparategroundingadviceprovidedintheproduct’ sdocumentation.
Moreinformation
Itisrecommendedthatbestpracticeisobservedinallvesselelectricalinstallations,asdetailed
inthefollowingstandards:
BMEACodeofPracticeforElectricalandElectronicInstallationsinBoats
NMEA0400InstallationStandard
ABYCE-11AC&DCElectricalSystemsonBoats
ABYCA-31BatterychargersandInverters
ABYCTE-4LightningProtection
Warning:Productgrounding
Beforeapplyingpowertothisproduct,ensureithasbeencorrectlygrounded,in
accordancewiththeinstructionsprovided.
Warning:Positivegroundsystems
Donotconnectthisunittoasystemwhichhaspositivegrounding.