4.4NMEA0183connection
NMEA0183devicescanbeconnectedtoyourMFDusingtheNMEA0183wiresonthesupplied
P
ower/Video/NMEA0183cable.
2NMEA0183portsareavailable:
Port1:Inputandoutput4,800or38,400baudrate.
Port2:Inputonly4,800or38,400baudrate.
Note:
TheBaudrateforeachportmustbesetinyourMFD
ssettings,refertotheoperationinstructions
foryourMFDfordetailsonspecifyingbaudrate.
ForPort1,boththeinputandoutputcommunicateatthesamebaudrate.Forexample,ifyou
haveoneNMEA0183deviceconnectedtoPort1INPUT,andanotherNMEA0183device
connectedtoPort1OUTPUT,bothNMEAdevicesmustusethesamebaudrate.
Upto4devicescanbeconnectedtothedisplay' soutputportandupto2devicestothedisplay's
inputports.
ItemDeviceCablecolorP ortInput/output
Positive(+)/
negative(-)
1White1InputP ositive
2Green
1InputNegative
3
Y ellow1
Output
Positive
4Brown1
Output
Negative
5
Orange/White
2
InputP
ositive
6
MFD
Orange/Green
2
InputNegative
7
**Output
P ositive
8**Output
Negative
9**
InputP ositive
10
NMEAdevice
**
InputNegative
11
**Output
P ositive
12
NMEAdevice
**Output
Negative
Note:
*R efertoinstructionsprovidedwithyourNMEA0183deviceforconnectiondetails.
Connections43