EasyManua.ls Logo

Raymarine AXIOM Series - Sonar Troubleshooting

Raymarine AXIOM Series
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6.5Sonartroubleshooting
Problemswiththesonarandtheirpossiblecausesandsolutionsaredescribedhere
.
Scrollingimageisnotbeingdisplayed
P
ossiblecausesPossiblesolutions
Sonardisabled
Select
PingEnablefromtheSonarapp
sSoundermenu.
Incorrecttransducerselected
CheckthatthecorrecttransducerisselectedintheSonar
app
sTransducermenu.
Damagedcables
1.Checkthatthetransducercableconnectorisfullyinserted
andlock
edinposition.
2.Checkthepowersupplycableandconnectorsforsigns
ofdamageorcorrosion,replaceifnecessary.
3.Withtheunitturnedon,tryflexingthecablenearto
thedisplayconnectortoseeifthiscausestheunitto
re-boot/loosepower,replaceifnecessary.
4.Checkthevessel’sbatteryvoltage,theconditionofthe
batteryterminalsandpowersupplycables,ensuring
connectionsaresecure,cleanandfreefromcorrosion,
replaceifnecessary.
5.Withtheproductunderload,usingamulti-meter,check
forhighvoltagedropacrossallconnectors/fusesetc(this
cancausetheSonarapplicationstostopscrollingorthe
unittoreset/turnoff),replaceifnecessary.
DamagedorfouledtransducerChecktheconditionofthetransducerensuringitisnot
damagedandisfreefromdebris/fouling,cleanorreplaceas
necessary .
W rongtransducerfitted
Ensurethetransduceriscompatiblewithyoursystem.
Externalsonarmodule:
Sea Talkhs/RayNetnetwork
problem.
Checkthattheunitiscorrectlyconnectedtothe
multifunctiondisplayorRaymarinenetworkswitch.Ifa
crossovercouplerorothercouplercable/adapterisused,
checkallconnectionsensuringconnectionsaresecure,
cleanandfreefromcorrosion,replaceifnecessary.
Externalsonarmodule:Software
mismatchbetweenequipment
maypreventcommunication.
EnsureallR
aymarineproductscontainthelatest
availablesoftware,checktheRaymarinewebsite:
www.raymarine.com/softwareforsoftwarecompatibility.
Nodepthreading/lostbottomlock
P ossiblecausesPossiblesolutions
T ransducerlocation
Checkthatthetransducerhasbeeninstalledinaccordance
withtheinstructionsprovidedwiththetransducer.
T ransducerangle
Ifthetransducerangleistoogreatthebeamcanmissthe
bottom,adjusttransducerangleandrecheck.
T ransducerkicked-up
Ifthetransducerhasakick-upmechanism,checkthatithas
notkickedupduetohittinganobject.
P owersourceinsufficient
Withtheproductunderload,usingamulti-meter,checkthe
powersupplyvoltageasclosetotheunitaspossibleto
establishactualvoltagewhenthecurrentisflowing.(Check
yourproduct’sT echnicalspecificationforpowersupply
requirements.)
DamagedorfouledtransducerChecktheconditionofthetransducerensuringitisnot
damagedandisfreefromdebris/fouling.
T roubleshooting
57

Table of Contents

Related product manuals