EasyManua.ls Logo

Raymarine RAY50 - 4.4 Power Connection

Raymarine RAY50
116 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
4.4Powerconnection
Thepowersupplyshouldbeconnectedasshown
below:
12 v dc +
12 v dc -
D13214-1
1
2
8
3
4
6
7 5
5
1.Basestation
2.Passivespeakerconnection.
3.NMEA0183wires
4.Loudhailerwires(Ray70only.)
5.In-line10Afuse
6.Redpositivewire
7.Blacknegativewire.
8.Vessel’s12Vdcpowersupply
Warning:12Voltdconly
Thisproductmustonlybeconnectedtoa
12voltdcpowersource.
Warning:Chassisgrounding
DoNOTgroundthisproductusingthe
chassisgroundterminal.
Groundingthisproducttoavessel’sRF
groundmaycausegalvaniccorrosion.
Grounding
Thisproductisgroundedthroughthe0Vdcnegative
wireonthepowercableanddoesnotrequireadrain
(shield)tobeconnectedtothebasestation’sground
terminal.
Warning:Positivegroundsystems
Donotconnectthisunittoasystemwhich
haspositivegrounding.
Breakers,fusesandcircuitprotection
Theinformationbelowisprovidedasguidance
tohelpprotectyourproduct.Theexample
illustrationsprovidedareforcommonvesselpower
arrangements,ifyouareunsurehowtoprovidethe
correctlevelofprotectionthenpleaseconsulta
Raymarineauthorizeddealerforsupport.
Distributionpanelconnection
Itisrecommendedthatyourproductiswiredthrough
yourvessel’sdistributionpanelviaathermalbreaker
orfuse.
D13092-1
2 31
4
5
1.Vesselpowersupplypositive(+)
2.In-linefuse.(Ifyourproduct’spowercabledoes
nothaveanin-linefusethenoneshouldbe
tted.)
3.Productpowercable
4.Vesselpowersupplynegative(-)
5.Vesseldistributionpanel
Batteryconnection
Yourproductmaybewireddirectlytothebattery
usinganin-linefuse.
D13091-1
2 41
5
3
1.Vesselpowersupplypositive(+)
2.Vesselpowersupplynegative(-)
3.In-linefuse.(Ifyourproduct’spowercabledoes
nothaveanin-linefusethenoneshouldbe
tted.)
4.Productpowercable
5.Vesselbattery
In-linefuseandthermalbreakerratings
Thefollowingin-linefuseandthermalbreakerratings
applytoyourproduct:
In-linefuseratingThermalbreakerrating
10A
7A(ifonlyconnectingone
device)
Note:
Thesuitablefuseratingforthethermalbreaker
isdependentonthenumberofdevicesyouare
connecting.Ifindoubtconsultanauthorized
Raymarine
®
dealer.
Yourproduct’spowercablemayhavetted
in-linefuse,ifnotthenyoucanaddanin-line
fusetothepositivewireofyourproductspower
connection.
30
Ray50/Ray60/Ray70

Table of Contents

Other manuals for Raymarine RAY50

Related product manuals