EasyManua.ls Logo

Raynor ControlHoist CMT - Page 21

Raynor ControlHoist CMT
44 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
21
7.2.1 D2 / D3 LED Monitoring Status Combination Scenarios
Table 5 - D2/D3 LED Monitoring Status - Combination Scenarios
Scenario
D2 LED
GREEN
D3 LED
RED
Functions
1 OFF OFF Indicates a DC power failure.
2 OFF Flash When door is closing.
3 ON OFF When operator is on standby.
4 ON Flash
Indicates wrong handing feature activation (if a limit switch is not
released/deactivated within 3.6 sec while door starts to close/open
from the fully open/closed positions).
5 ON ON Indicates that JP2 is not properly set.
6 Flash OFF When door is opening.
7 Flash Flash When timer to close is counting before closing the door.
8 Flash Flash
When door is opening during programming of the run timer or the
mid-stop features. Refer to section 7.3.2, p.23 as reference.
For technical support, please call 1-800-4-Raynor (1-800-472-9667) or visit www.raynor.com

Related product manuals