INSTALLATION & OPERATING
INSTRUCTIONS
Gas-Fired
Pool & Spa
Heater
Catalog No. 6000.59U Effective: 10-06-10 Replaces: 06-10-10 P/N 241236 Rev. 22
WARNING: If these instructions are not followed exactly, a fire or explosion may result
causing property damage, personal injury or death.
WHAT TO DO IF YOU SMELL GAS:
Do not try to light any appliance.
Do not touch any electrical switch; do not use any phone in your building.
Immediately call your gas supplier from a neighbor's phone. Follow the gas sup-
plier's instructions.
If you cannot reach your gas supplier, call the fire department.
Installation and service must be performed by a qualified installer, service agency or
the gas supplier.
This manual should be maintained in legible condition and kept adjacent to the heater or in a safe place for future
reference.
Atmospheric Models
206A, 266A, 336A & 406A
Lo NOx Models
207A, 267A, 337A & 407A
Do not store or use gasoline or other flammable vapors and liquids in the vicinity of
this or any other appliance.

Table of Contents

Other manuals for Raypak 207A

Questions and Answers

  • S
    Sean JuarezAug 27, 2025
    What to do if Raypak 207A Gas Heater combustion fan is not running?
    • D
      David SimsAug 27, 2025
      If the combustion fan in your Raypak Gas Heater isn't running, it could be due to a few reasons. The fan relay might be faulty, requiring replacement. There could be a loose connection or a failed motor in the fan itself. A burned motor due to incorrect wiring could also be the cause, necessitating blower replacement. Finally, the air pressure switch might need replacing.
  • C
    Charles WalkerAug 27, 2025
    What to do if my Raypak 207A takes too long to heat pool or spa?
    • B
      Brandon SheltonAug 27, 2025
      If your Raypak Gas Heater is taking too long to heat your pool or spa, consider these potential causes: * The heater might be undersized. Calculate the heating capacity of the heater using the formula: Heater output (BTUH) = Pool gallonage x 8.33, or refer to the heater sizing chart. * The filter might not be running long enough; reset the time clock. * The filter could be dirty; clean the filter. * The gas line or meter may be undersized; refer to the installation instructions.
  • W
    William ArroyoAug 25, 2025
    What to do if the combustion fan is not running on my Raypak Gas Heater?
    • W
      William Jordan DDSAug 26, 2025
      If the combustion fan in your Raypak Gas Heater is not running, it could be due to several reasons. The fan relay might be faulty, so replace it. There might be a loose connection or a failed motor in the fan itself. A burned motor due to incorrect wiring could also be the cause, so replace the blower. Finally, the air pressure switch might need replacement.
  • K
    Kevin BurkeAug 23, 2025
    Why does my Raypak 207A Gas Heater have a yellow lazy flame?
    • J
      Jennifer JohnsonAug 25, 2025
      If your Raypak Gas Heater is producing a yellow, lazy flame, it could be due to low gas pressure, in which case you should adjust the gas pressure. Another potential cause is insects or debris clogging the burner intake ports; if this is the case, clean the burners.

Summary

OWNERS OPERATING INSTRUCTIONS

START-UP PROCEDURES

Guide for initial setup and operation of the pool/spa heater.

MILLIVOLT LIGHTING & SHUT-OFF

Steps for lighting and shutting down the millivolt system.

ELECTRONIC IGNITION OPERATING & SHUT-OFF

Steps for lighting and shutting down the electronic ignition system.

CAUTIONS AND SAFETY GUIDELINES

Important safety information regarding water temperature and user precautions.

MAINTENANCE AND CARE PROCEDURES

Routine maintenance tasks and troubleshooting for non-firing issues.

POOL & SPA WATER CHEMISTRY

Maintaining balanced water chemistry to protect the heater and equipment.

COLD WEATHER OPERATION AND WINTERIZING

Procedures for operating and winterizing the heater in cold climates.

INSTALLATION AND SERVICE INSTRUCTIONS

RECEIVING EQUIPMENT

Instructions for checking and receiving the heater unit upon delivery.

GENERAL SPECIFICATIONS

Technical specifications including ambient temperature ratings and altitude adjustments.

INSTALLATION INSTRUCTIONS & CODE REQUIREMENTS

Important notices, warnings, and code requirements for installation.

CLEARANCES AND VENTING REQUIREMENTS

Required clearances and venting considerations for safe installation.

GAS SUPPLY CONNECTIONS & PIPING

Guidelines for gas supply connections, pipe sizing, and vent piping.

PLUMBING-WATER CONNECTIONS

Diagrams and guidelines for plumbing water connections for the heater.

SERVICING AND TROUBLESHOOTING

GENERAL LOCATION OF CONTROLS

Identifies the location of various controls on Atmospheric and Lo NOx units.

CONTROL PANEL REMOVAL & ADJUSTMENTS

Steps for panel removal and adjusting control settings on various models.

DIGITAL THERMOSTAT OPERATION AND SETTINGS

Explanation of digital thermostat operation, modes, and settings.

FAULT HISTORY AND PROGRAMMING FUNCTIONS

Accessing fault history and programming functions for advanced settings.

DIAGNOSTICS, STATUS, AND FAULT CODES

Information on diagnostic readouts, status, and fault codes.

REMOTE CONTROL INSTALLATION AND OPERATION

Instructions for installing and operating remote controls.

SWITCHES AND SAFETY COMPONENTS

Connecting switches and understanding safety components like pressure and roll-out switches.

TROUBLESHOOTING GUIDE

Common problems, causes, and solutions for heater issues.

ELECTRICAL TROUBLESHOOTING FLOW CHARTS

Flow charts for diagnosing electrical and control logic issues.

REPLACEMENT PARTS

ATMOSPHERIC HEATERS PARTS LIST

Detailed list of replacement parts for atmospheric heaters.

LO NOx HEATERS PARTS LIST

Detailed list of replacement parts for Lo NOx heaters.

Raypak 207A Specifications

General IconGeneral
BrandRaypak
Model207A
CategoryGas Heater
LanguageEnglish