42
Figure 7-4 Piping of IB boilers model 199
7 - INSTALLATION - IB boiler water connections
1 = IB Boiler
2 = Air separator
3 = Ball valve
4 = Drain valve
5 = Filling valve
6 = Expansion tank
7 = Filter
8 = Back ow preventer
9 = Local boiler pump
12 = Manual gas shut-off valve (Install manual shut-off
valve 5 ft (1.5m) above oor)
13 = Ground joint union
15 = Indirect water heater pump (DHW pump) (if needed)
16 = Heating pump (CH pump)
Heating
system
return
Supply to a
DHW indirect
water heater
(if needed)
Return from a
DHW indirect
water heater (if
needed)
Gas inlet
Heating
system
supply
Cold
water
make-up
CAUTION!!!
This is a
concept drawing only. It is
up to the system designer
to determine the necessary
components, including
additional equipment and
any safety devices which
in the judgement of the
designer are appropriate,
in order to properly size,
con gure and design
that system and to
ensure compliance with
building and safety code
requirements.

Table of Contents

Other manuals for RBI infinite energy 2

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the RBI infinite energy 2 and is the answer not in the manual?

RBI infinite energy 2 Specifications

General IconGeneral
BrandRBI
Modelinfinite energy 2
CategoryBoiler
LanguageEnglish

Related product manuals