EasyManuals Logo

RCS EPSILON ES4 User Manual

RCS EPSILON ES4
68 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background imageLoading...
Page #38 background image
38
42 ES2XL-1914 1400…1900
52 ES2XL-2119 1900…2100
62 ES2XL-2221 2100…2200
72 ES2XXL-2722 2200…2700
82 ES2XXL-2927 2700…2900
92 ES2XXL-3029 2900…3000
A2.3.2.1.4 Reading of serial number and date of production (command 42h).
The command is designed for reading of following FLS parameters: date of production, serial
number, model code, embedded software version.
Command format:
Drift, byte
Value Description
0 1 31h Prefix
+1 1 00h…FFh
Network address of
acceptor
+2 1 42h Command code
+3 1 00h…FFh CRC8
Answer format:
Drift, byte
Value Description
0 1 3Eh Prefix
+1 1 00h…FFh
Network address of
sender
+2 1 42h Command code
+3 1 00h…FFh
Year of production: 00h
corresponds to 2000
+4 1 00h…0Bh
Month of production:
00h – January, … , 0Bh
- December
+5 1 01h…1Fh
Day of production:
1…31
+6 3 000005h…FFFFFFh
Serial number
(000005…1048575)
+9 1 01h…92h
Model code
(see table 4.1)
+10 1 01h…FFh
Embedded software
version
+11 1 00h…FFh CRC8
A2.3.2.1.5 Reading of supply voltage (command 50h).
Command is designed for getting current value of voltage of built-in stabilizer.
Command format:
Drift, byte
Value Description
0 1 31h Prefix

Questions and Answers: