Door control
FireProV2
Manual
Please keep this manual with attachments carefully!
33
11.2 Parameter settings 1. :
Parameter
Description
Settings
1.1
End position open
Open the door/roller shutter to the desired end
position and then press the stop/ok button on
the print to confirm or press the lid button to
cancel.
1.2
End position closed
Close the door/roller shutter to the desired end
position and then press the stop/ok button on
the print to confirm or stop button on lid to
cancel.
1.3
Fine adjustment end
position open
Adjust open position upwards or down.
+/- 0 t/m 9.
1.4
Fine adjustment end
position close
Adjust close position upwards or down.
+/- 0 t/m 9.
1.5
Adjust pre end position
close
Adjust pre end position upwards or down+/- 0
t/m 9.
1.6
Partial opening for fire
escape (Parameter 1.7
must be set )
.1 Switched off, door opens completely in case
of fire
.2 Enabled, door goes to the set position when
fire, parameter 1.7.
1.7
Partial opening for fire
functions
Desired end position partial open escape when
fire. Send the door/roller shutter to the desired
position and then press the stop/ok button on
the print to confirm or press stop button on lid
to cancel.
1.9
Fine adjustment
overclose limit switch
Adjust Overclose" position upwards or down.
+/- 0 up to 9.
(limit switch, to allow the door to close in case
of fire, smoke or low battery voltage further
than at normal operation or as partial opening
when escape in case of fire, smoke or low
battery voltage (parameter 2.1) or stopover
(parameter (4.1 and 4.2)).