Brooklands Case Controller | Document Revision 2.2c
www.resourcedm.com
10
Servicing
There are no serviceable parts. The only parts that are replaceable on this tray are the front panel mounted
fuses. If replacement fuses are required they must match the original size.
Fuses: HRC conforming to IEC60127 (32 x 6.3mm)
Fans (F1) 3.15A (T)
Lights (F2) 3.15A (T)
Controller (F3) 0.25A (F)
Valve (F4) 0.25A (T)
Fuse rating may vary depending on the age of the tray so please check with the controller label for tray you
are using.
Inputs and Outputs
Inputs
Range
Step
Units
PR0029L LLV
PR0029L/37 LLV
230V ACF
PR0029L/37 EEV
230V ACF
PR0033 LLV
PR033E EEV
Control temp.
-49.0 to 60.0
0.1
Deg C
Air on temp.
-49.0 to 60.0
0.1
Deg C
Air off temp.
-49.0 to 60.0
0.1
Deg C
Air on Left
-49.0 to 60.0
0.1
Deg C
Air off Left
-49.0 to 60.0
0.1
Deg C
Air on Right
-49.0 to 60.0
0.1
Deg C
Air off Right
-49.0 to 60.0
0.1
Deg C
Product Probe
-49.0 to 60.0
0.1
Deg C
Evaporator Probe
-49.0 to 60.0
0.1
Deg C
Suc. Line Probe
-49.0 to 60.0
0.1
Deg C
Fan Fail
Alm/Ok
-
-
Superheat
-49.0 to 60.0
0.1
Deg C
Rem Evap Temp.
-49.0 to 60.0
0.1
Deg C
MOP
Off/On
-
-
CO2
Off/On
-
-
EEV Opening
0 to 100
0.1
%
LLV
Closed/ Open
-
-
Trim Heater
Off/On
-
-
Case Fans
Off/On
Lights
Off/On
PWM
0 to 100
1
%
Last Def. Time
00:00 to 23:59
00:01
hh:mm
Last Def. Length
00:00 to 03:00
00:01
hh:mm
Last Def. Ctrl
Temp.
-49.0 to 60.0
0.1
Deg C
Last Def. Type
None/ Internal/
External/
Network/
Timed/ Forced
-
-