Bulletin No. G306A-G
Drawing No. LP0666
Released 02/13
MODEL G306A - GRAPHIC COLOR LCD OPERATOR INTERFACE TERMINAL
WITH TFT QVGA DISPLAY AND TOUCHSCREEN
CONFIGURED USING CRIMSON
®
SOFTWARE
(BUILD 424 OR NEWER)
UP TO 5 RS-232/422/485 COMMUNICATIONS PORTS
(2 RS-232 AND 1 RS-422/485 ON BOARD, 1 RS-232 AND 1
RS422/485 ON OPTIONAL COMMUNICATIONS CARD)
10 BASE T/100 BASE-TX ETHERNET PORT TO NETWORK UNITS
AND HOST WEB PAGES
USB PORT TO DOWNLOAD THE UNIT’S CONFIGURATION FROM
A PC OR FOR DATA TRANSFERS TO A PC
UNIT’S CONFIGURATION IS STORED IN NON-VOLATILE
MEMORY (8 MBYTE FLASH)
COMPACTFLASH
®
SOCKET TO INCREASE MEMORY CAPACITY
5.7-INCH TFT ACTIVE MATRIX 256 COLOR QVGA 320 X 240
PIXEL LCD W/LED BACKLIGHT
5-BUTTON KEYPAD FOR ON-SCREEN MENUS
THREE FRONT PANEL LED INDICATORS
POWER UNIT FROM 24 VDC ±20% SUPPLY
RESISTIVE ANALOG TOUCHSCREEN
U
FOR USE IN HAZARDOUS LOCATIONS:
Class I, Division 2, Groups A, B, C, and D
C
R
L
US LISTED
43NH
PROCESS CONTROL EQUIPMENT
GENERAL DESCRIPTION
CONTENTS OF PACKAGE
- G306A Operator Interface.
- Panel gasket.
- Template for panel cutout.
- Hardware packet for mounting unit into panel.
- Terminal block for connecting power.
The G306A Operator Interface Terminal combines unique capabilities
normally expected from high-end units with a very affordable price. It is built
around a high performance core with integrated functionality. This core allows
the G306A to perform many of the normal features of the Paradigm range of
Operator Interfaces while improving and adding new features.
The G306A is able to communicate with many different types of hardware
using high-speed RS232/422/485 communications ports and Ethernet 10 Base
T/100 Base-TX communications. In addition, the G306A features USB for fast
downloads of configuration files and access to trending and data logging. A
CompactFlash socket is provided so that Flash cards can be used to collect your
trending and data logging information as well as to store larger configuration files.
In addition to accessing and controlling of external resources, the G306A
allows a user to easily view and enter information. Users can enter data through
the touchscreen and/or front panel 5-button keypad.
ORDERING INFORMATION
SAFETY SUMMARY
All safety related regulations, local codes and instructions that appear in the
manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.
Do not use the controller to directly command motors, valves, or other
actuators not equipped with safeguards. To do so can be potentially harmful to
persons or equipment in the event of a fault to the controller.
The protective conductor terminal is bonded to conductive
parts of the equipment for safety purposes and must be
connected to an external protective earthing system.
1
Contact your Red Lion distributor or
complete selection.
visit our website for
WARNING - EXPLOSION HAZARD - SUBSTITUTION OF
COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I,
DIVISION 2
2
Use this part number to purchase the Crimson
®
software on CD with a
printed manual, USB cable, and RS-232 cable. Otherwise, download for
free from www.redlion.net.
3
Red Lion offers RJ modular jack adapters. Refer to the DR literature for
complete details.
4
Battery type is lithium coin type CR2025.
5
Industrial grade two million write cycles.
CompactFlash is a registered trademark of CompactFlash Association.
1
CAUTION: Risk Of Danger. CAUTION: Risk of electric shock.
Read complete instructions prior to
installation and operation of the unit.
MODEL NO. DESCRIPTION PART NUMBER
G306A
Operator Interface for indoor applications,
textured finish with embossed keys
G306A000
G3CF CompactFlash Card
5
G3CFxxxx
G3RS RS232/485 Optional Communication Card G3RS0000
G3CN CANopen Optional Communication Card G3CN0000
G3DN
DeviceNet option card for G3 operator interfaces
with isolated high speed communications ports
G3DN0000
G3PBDP Profibus DP Optional Communication Card G3PBDP00
SFCRM2 Crimson 2.0
2
SFCRM200
CBL RS-232 Programming Cable CBLPROG0
USB Cable CBLUSB00
Communications Cables
1
CBLxxxxx
DR DIN Rail Mountable Adapter Products
3
DRxxxxxx
Replacement Battery
4
BNL20000
G3FILM Protective Films G3FILM06
Question and Answer IconNeed help?

Do you have a question about the red lion G306A and is the answer not in the manual?

red lion G306A Specifications

General IconGeneral
Brandred lion
ModelG306A
CategoryTouch terminals
LanguageEnglish

Summary

G306A General Description

G306A General Description

Provides an overview of the G306A Operator Interface Terminal's capabilities and features.

G306A Safety Summary

G306A Safety Summary

Outlines critical safety regulations, local codes, and instructions for safe operation and installation.

G306A Specifications

G306A Power Requirements

Specifies the electrical power requirements for the G306A unit.

G306A Environmental Conditions

Specifies the operating and storage environmental conditions.

G306A Certifications and Compliances

Lists safety and electromagnetic compliance certifications for the G306A.

G306A EMC Compliance

Details EMC standards and immunity requirements for industrial locations.

Installing and Powering the G306A

G306A Mounting Instructions

Provides step-by-step instructions for mounting the G306A into a panel.

G306A Power Supply Requirements

Details the necessary power supply specifications and mounting recommendations.

Communicating with the G306A

Configuring the G306A

Explains how to configure the G306A using Crimson software via various ports.

G306A Ethernet Communications

Details Ethernet communication setup and LED status indicators.

G306A RS232 Ports

G306A RS232 Ports Overview

Describes the two RS232 ports (PGM and COMMS) and their uses.

G306A RS422/485 Comms Port

Details the RS422/485 port and its configuration options.

G306A Software and Unit Operation

G306A Crimson Software

Information on the Crimson software for configuration and updates.

G306A Troubleshooting

Provides guidance for troubleshooting common issues with the G306A.

G308 General Description

G308 General Description

Provides an overview of the G308 Operator Interface Terminal's capabilities and features.

G308 Safety Summary

G308 Safety Summary

Outlines critical safety regulations, local codes, and instructions for safe operation and installation.

G308 Specifications

G308 Power Requirements

Specifies the electrical power requirements for the G308 unit.

G308 Environmental Conditions

Specifies the operating and storage environmental conditions.

G308 Certifications and Compliances

Lists safety and electromagnetic compliance certifications for the G308.

G308 EMC Compliance

Details EMC standards and immunity requirements for industrial locations.

Installing and Powering the G308

G308 Mounting Instructions

Provides step-by-step instructions for mounting the G308 into a panel.

G308 Power Supply Requirements

Details the necessary power supply specifications and mounting recommendations.

Communicating with the G308

Configuring the G308

Explains how to configure the G308 using Crimson software via various ports.

G308 Ethernet Communications

Details Ethernet communication setup and LED status indicators.

G308 RS232 Ports

Describes the two RS232 ports (PGM and COMMS) and their uses.

G308 RS422/485 Comms Port

G308 RS422/485 Comms Port

Details the RS422/485 port and its configuration options.

G308 Software and Unit Operation

G308 Crimson Software

Information on the Crimson software for configuration and updates.

G308 Troubleshooting

Provides guidance for troubleshooting common issues with the G308.

G310 General Description

G310 General Description

Provides an overview of the G310 Operator Interface Terminal's capabilities and features.

G310 Safety Summary

G310 Safety Summary

Outlines critical safety regulations, local codes, and instructions for safe operation and installation.

G310 Specifications

G310 Power Requirements

Specifies the electrical power requirements for the G310 unit.

G310 Environmental Conditions

Specifies the operating and storage environmental conditions.

G310 Certifications and Compliances

Lists safety and electromagnetic compliance certifications for the G310.

G310 EMC Compliance

Details EMC standards and immunity requirements for industrial locations.

Installing and Powering the G310

G310 Mounting Instructions

Provides step-by-step instructions for mounting the G310 into a panel.

G310 Power Supply Requirements

Details the necessary power supply specifications and mounting recommendations.

Communicating with the G310

Configuring the G310

Explains how to configure the G310 using Crimson software via various ports.

G310 RS232 Ports

Describes the two RS232 ports (PGM and COMMS) and their uses.

G310 RS422/485 Comms Port

G310 RS422/485 Comms Port

Details the RS422/485 port and its configuration options.

G310 Software and Unit Operation

G310 Crimson Software

Information on the Crimson software for configuration and updates.

G310 Troubleshooting

Provides guidance for troubleshooting common issues with the G310.

G315C General Description

G315C General Description

Provides an overview of the G315C Operator Interface Terminal's capabilities and features.

G315C Safety Summary

G315C Safety Summary

Outlines critical safety regulations, local codes, and instructions for safe operation and installation.

G315C Specifications

G315C Power Requirements

Specifies the electrical power requirements for the G315C unit.

G315C Certifications and Compliances

Lists safety and electromagnetic compliance certifications for the G315C.

Installing and Powering the G315C

G315C Mounting Instructions

Provides step-by-step instructions for mounting the G315C into a panel.

G315C Power Supply Requirements

Details the necessary power supply specifications and mounting recommendations.

Communicating with the G315C

Configuring the G315C

Explains how to configure the G315C using Crimson software via various ports.

G315C RS232 Ports

G315C RS232 Ports

Describes the two isolated RS232 ports and their uses.

G315C RS422/485 Comms Port

Details the RS422/485 ports and their configuration options.

G315C Software and Unit Operation

G315C Crimson Software

Information on the Crimson software for configuration and updates.

G315C Troubleshooting

Provides guidance for troubleshooting common issues with the G315C.

Red Lion Panel Meter Specifications

Panel Meter Solutions and Flexibility

Crimson Software for Panel Meters

Highlights the benefits and ease of use of Crimson software.

Panel Meter Specifications Overview

Related product manuals