-4-
Drawing No. LP0951D Released 2017-10-31
CONTROL AND ALARM OUTPUT CONNECTIONS
LOAD
AC/DC
Power (-)
LOAD
COMM
NO
NO
AC/DC
Power (+)
AL 2
AL 1
AC/DC
Power
LOAD
COMM (-)
NO (+)
AC Powe
SSR
COMM (-)
NO (+)
POWER
UNIT
+
-
AC
AC
Alarm 1 and 2 * (1/16 DIN Shown)
OP1/OP2 Output Control Relay *
OP1 Output Control Logic/SSR *
USER INPUT CONNECTIONS *
User 1
+
User 2
+
-
-
RS 485 CONNECTIONS *
D+
D-
RS485
RECEIVING
DEVICE
+
-
RS-485
ANALOG INPUT
CONTROL
DEVICE
COMM (-)
NO (+)
IN +
IN -
OP1 Output Control Analog *
* See unit label for terminal identification.
USER 2/RETRANS
+
-
-
+
IN-
IN+
ANALOG INPUT
CONTROL
DEVICE
Analog Output (Retrans)*
LIMITED WARRANTY
(a) Red Lion Controls Inc. (the “Company”) warrants that all Products shall be free from defects in material and workmanship under
normal use for the period of time provided in “Statement of Warranty Periods” (available at www.redlion.net) current at the time of
shipment of the Products (the “Warranty Period”). EXCEPT FOR THE ABOVE-STATED WARRANTY, COMPANY MAKES NO
WARRANTY WHATSOEVER WITH RESPECT TO THE PRODUCTS, INCLUDING ANY (A) WARRANTY OF MERCHANTABILITY;
(B) WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE; OR (C) WARRANTY AGAINST INFRINGEMENT OF
INTELLECTUAL PROPERTY RIGHTS OF A THIRD PARTY; WHETHER EXPRESS OR IMPLIED BY LAW, COURSE OF
DEALING, COURSE OF PERFORMANCE, USAGE OF TRADE OR OTHERWISE. Customer shall be responsible for determining
that a Product is suitable for Customer’s use and that such use complies with any applicable local, state or federal law.
(b) The Company shall not be liable for a breach of the warranty set forth in paragraph (a) if (i) the defect is a result of Customer’s
failure to store, install, commission or maintain the Product according to specifications; (ii) Customer alters or repairs such Product
without the prior written consent of Company.
(c) Subject to paragraph (b), with respect to any such Product during the Warranty Period, Company shall, in its sole discretion,
either (i) repair or replace the Product; or (ii) credit or refund the price of Product provided that, if Company so requests, Customer
shall, at Company’s expense, return such Product to Company.
(d) THE REMEDIES SET FORTH IN PARAGRAPH (c) SHALL BE THE CUSTOMER’S SOLE AND EXCLUSIVE REMEDY AND
COMPANY’S ENTIRE LIABILITY FOR ANY BREACH OF THE LIMITED WARRANTY SET FORTH IN PARAGRAPH (a).
ORDERING INFORMATION
PXU
0
MAIN CONTROL
OUT 1
OPTIONS ◊
0 - None
A - 485/ 2 User Inputs
B - CT Input/ 485/ 1 User Input
C - Retransmitted Analog Output/ 485/ 1 User Input
D - Remote Setpoint Input/ 485/ 1 User Input
DIN SIZE/POWER
2 - 1/16 AC B - 1/16 DC
3 - 1/8 Vert AC C - 1/8 Vert DC
5 - 1/4 AC E - 1/4 DC
◊ Options selections A, B, C, & D require Secondary Control (OUT2) selection to be 1.
- The unit must have 485 option to program the unit using Crimson.
Not all option configurations are available. Available part numbers can be viewed at www.redlion.net/PXU.
SECONDARY
CONTROL
OUT 2
1 - Relay
2 - SSR Drive
3 - 4-20 mA
4 - 0-10 V
0 - None
1 - Relay ◊