PXU Series
Temperature/Process Controllers
For Firmware Version 1.5 or Above
Hardware Guide | Jan 2018
LP0932 | Revision E

Questions and Answers

  • K
    Kenneth FrancoAug 4, 2025
    Why can't I access programming on my red lion PXU10020 Controller?
    • P
      penawendyAug 5, 2025
      If you cannot access programming on your Red Lion Controller, it could be because an active User Input is programmed for PLOC; deactivate the User Input. Alternatively, you may have entered an incorrect access code. Enter the proper access code at the CodE 0 prompt (111 or -111 is the universal access code).
  • G
    Gerald RussellAug 9, 2025
    Why is there no display on my Red Lion Controller?
    • J
      Joseph ChenAug 9, 2025
      If there is no display on your Red Lion Controller, it could be due to several reasons. First, check if the power is off. Second, a brown-out condition might be present, so verify the power reading. Third, there might be a loose connection or improper wiring, so check all connections. Lastly, ensure the controller is fully seated into the case by checking the installation.
  • B
    Brandon JimenezAug 13, 2025
    What to do if red lion PXU10020 shows '????' in the top display?
    • J
      Joe FloresAug 13, 2025
      If your Red Lion Controller displays '????' in the top display, it could be due to several reasons. It may be that the input exceeds the range of the controller, so check the input parameters. Alternatively, the temperature might exceed the range of the input probe, so change to an input sensor with a higher temperature range. Also, the transmitter or probe could be defective or incorrect, so replace them. Finally, the temperature may be too high for the probe, so reduce the temperature.
  • J
    Jeffrey RobertsAug 17, 2025
    What to do if red lion PXU10020 shows ' . . . ?. . .' or 'IN' in display?
    • J
      jonesrandyAug 17, 2025
      If your Red Lion Controller displays ' . . . ?. . .' or 'IN', it might be because the display value exceeds the 4-digit display range, so check the input parameters. Another reason could be a defective or miscalibrated cold junction circuit, so change the display resolution or scaling.
  • M
    Matthew HillAug 22, 2025
    Why is my Red Lion Controller sluggish or not stable?
    • J
      Julie EllisAug 22, 2025
      If your Red Lion Controller is sluggish or not stable, it could be due to incorrect PID values. Also, the probe location could be incorrect; evaluate its placement.
  • C
    Christina WilsonAug 26, 2025
    What to do if red lion PXU10020 Controller shows '????' in display?
    • J
      Joseph KingAug 26, 2025
      If your Red Lion Controller displays '????' in the display, it could be due to a disconnected probe, so check the probe wire or change the probe. Another reason might be a broken or burned-out probe, so check the sensor input type selection.
  • S
    Stacey HoweAug 31, 2025
    What to do if Red Lion Controller shows '????' in top display?
    • D
      Daniel HernandezAug 31, 2025
      If your Red Lion Controller displays '????' in the top display, it could be because the input is below the range of the controller, so check the input parameters. It may also be that the temperature is below the range of the input probe, so change to an input sensor with a lower temperature range. Also, the transmitter or probe could be defective or incorrect, so replace the transmitter or probe. Finally, the temperature may be excessively low for the probe, so raise the temperature.

Summary

Safety Summary

General Specifications

Installation and Setup

Controller Installation Procedures

Step-by-step guides for installing 1/16, 1/8, and 1/4 DIN units.

Wiring Connections Guidelines

General advice for making secure and compliant electrical connections.

Programming Loops

Configuration Modules

Module 2: Output Parameters

Configuration for control outputs, limits, and scaling.

Module 4: Alarm Parameters

Configuration for alarm actions, values, and conditions.

Module 5: Control Parameters

PID control tuning and group settings.

Serial Communications and Configuration

Troubleshooting

Control Mode and PID Tuning

PID Tuning Explanations

Guidance on Auto-Tune and Manual Tuning.

Setpoint Profile Operation

red lion PXU10020 Specifications

General IconGeneral
ModelPXU10020
Input Voltage100-240 VAC
Power Consumption10 W
Enclosure RatingIP65
CertificationsCE, UL
Output TypeRelay
Communication ProtocolModbus RTU
Operating Temperature0 to 50°C