P5 P1
34
10 - LOADING THE PELLETS
OPERATING MODE
ADJUSTMENTS MENU
"Adjustments" menu settings determine the operation mode of the stove.
To access the menu, proceed as follows:
• Press the - + keys
• Scroll with the <> arrows and select "Set Amb. T" or "Set Ventilation T" or "Set Flame"
• Press "menu" to enter the option selected.
• Change with the + - keys.
• Press "menu" to conrm and "esc" to exit.
Set Amb. T - this function allows you to set the temperature you want to reach in the room where the stove is installed, from a minimum
of 5°C to a maximum of 35°C. When the said temperature is reached, the stove places itself in a status that is equivalent to the minimum
consumption values (minimum ame and hot air fan speed) to then start again when the set room temperature goes below the set
threshold.
PLEASE NOTE: The point to the right of the room temperature on the control panel display indicates the half degrees (e.g. 23.°C is
equivalent to 23.5°C).
Set Vent. - this function allows you to select the desired speed of the room fan from 1 to 5.
Flame Set - this function allows you to set the power of the ame from a minimum of 1 to a maximum of 5. The power levels correspond
to a dierent value of fuel consumption, setting 5 heats the room in less time and setting 1 can keep the room temperature stable for a
longer period of time. The set ame is automatically set to a minimum when the set temperature value is reached.
if the bars are all full, the stove is on ame power 5
if only one bar is full, the stove is on ame power 1
if the bars are ashing, automatic cleaning is in progress