VENT-FREE GAS WALL
HEATER
OWNER’S OPERATION AND
INSTALLATION MANUAL
BLUE FLAME MODEL
BWH10NLMC-2
WARNING: If the information in this manual is not
followed exactly, a re or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other ammable va-
pors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbors
phone. Follow the gas suppliers instructions.
If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by a quali-
ed installer, service agency or the gas supplier.
WARNING: This appliance is equipped for Natural and
Propane gas. Field conversion is not permitted other than
between natural or propane gases.
Questions, problems, missing parts?
Before returning to your retailer, call our customer service department at
1-800-229-5647, 8:00 am - 4:30 pm EST, Monday through Friday

Questions and Answers

  • A
    Adam MooreSep 4, 2025
    Why does my ReddyHeater BWH10NLMC-2 make a whistling noise when the burner is lit?
    • A
      angelwilsonSep 4, 2025
      A whistling noise when the burner is lit can be caused by several factors: * Turning the control knob to the high position when the burner is cold; turn the control knob to the low position and let it warm up for a minute. * Air in the gas line; operate the burner until the air is removed from the line and have the gas line checked by your local gas supplier. * Blocked air passageways; ensure minimum installation clearances are observed. * A dirty or partially clogged burner orifice; clean the burner.
  • C
    Crystal WatsonSep 18, 2025
    What to do if the ODS/pilot lights but the flame goes out when the control knob is released on my ReddyHeater Heater?
    • B
      basstylerSep 18, 2025
      If the ODS/pilot lights but the flame goes out when the control knob is released, ensure the control knob is fully pressed in and held for at least 30 seconds after the ODS/pilot lights. Check that the equipment shutoff valve is fully open. Also, make sure the thermocouple connection is snug at the control valve, hand tighten it and then tighten it 1/4 turn more. The pilot flame might not be touching the thermocouple, which allows the thermocouple to cool, causing the pilot flame to go out. This could be due to low gas pressure (contact your local gas company) or a dirty/partially clogged ODS/pilot (clean or replace the ODS/pilot assembly). A damaged thermocouple or control valve could also be the problem, so replace them if necessary.
  • B
    Brittney PetersSep 16, 2025
    Why is there white powder residue forming within the burner box of my ReddyHeater BWH10NLMC-2 Heater?
    • J
      Juan ByrdSep 16, 2025
      When heated, the vapors from furniture polish, wax, carpet cleaners, etc., turn into white powder residue. Turn the heater off when using furniture polish, wax, carpet cleaner, or similar products.
  • A
    Alyssa BrownSep 14, 2025
    What to do if my ReddyHeater BWH10NLMC-2 Heater has a spark at ODS/pilot but no ignition when ignitor button is pressed?
    • D
      David Rivera MDSep 15, 2025
      If there is a spark at the ODS/pilot but no ignition when the ignitor button is pressed, it could be due to several reasons. Ensure the gas supply is turned on and the equipment shutoff valve is open. Make sure the control knob is fully pressed in while pressing the ignitor button. If there is air in the gas lines, continue holding down the control knob and repeat the igniting operation until the air is removed. The ODS/pilot may be clogged; clean or replace the ODS/pilot assembly. Incorrect inlet gas pressure or a damaged inlet regulator setting can also cause this; check the inlet gas pressure or replace the inlet gas regulator. Verify the control knob is in the PILOT position. Finally, if you are using propane, the gas supply may be depleted; contact your local propane/LP gas company.
  • F
    Frank WolfSep 12, 2025
    What does it mean if there's slight smoke or odor during initial operation of my ReddyHeater BWH10NLMC-2 Heater?
    • W
      Wayne PattersonSep 13, 2025
      A slight smoke or odor during the initial operation is due to residues from the manufacturing process. This problem will stop after a few hours of operation.
  • K
    Kevin SandersSep 12, 2025
    What to do if my ReddyHeater BWH10NLMC-2 Heater has no spark at the ODS/pilot when the ignitor button is pressed?
    • P
      Paul BrockSep 12, 2025
      If there is no spark at the ODS/pilot when the ignitor button is pressed, several issues could be the cause. The ignitor electrode may be positioned wrong or broken, in which case, replace the electrode. The ignitor electrode might not be connected to the ignitor cable, so replace the ignitor cable. The ignitor cable could be pinched or wet; free the ignitor cable if it is pinched and keep it dry. A broken ignitor cable will also cause this, so replace the ignitor cable. Lastly, a bad piezo ignitor can be the problem, so replace the piezo ignitor.
  • R
    Ross NguyenSep 9, 2025
    What causes delayed ignition of burner(s) in my ReddyHeater BWH10NLMC-2?
    • L
      laura91Sep 9, 2025
      Delayed ignition of the burner(s) can be caused by manifold pressure that is too low. Contact your local gas supplier. Another cause can be a clogged burner orifice, so clean the burner.
  • L
    longeileenSep 7, 2025
    Why does my ReddyHeater BWH10NLMC-2 Heater produce a clicking/ticking noise after the burner is lit or shut off?
    • C
      Christopher FloresSep 7, 2025
      A clicking or ticking noise just after the burner is lit or shut off is often because metal is expanding while heating or contracting while cooling. This is common with most heaters. If the noise is excessive, contact a qualified service technician.
  • N
    Nancy RogersSep 5, 2025
    What to do if my ReddyHeater BWH10NLMC-2 pilot will not light when using natural gas?
    • E
      Elizabeth ReynoldsSep 5, 2025
      If you are using natural gas and the pilot will not light, it may be because the inlet pressure exceeds 9.5" WC. Bypass the pressure switch.
  • D
    David GarciaAug 21, 2025
    Why does my ReddyHeater BWH10NLMC-2 smell like gas during combustion?
    • H
      hbanksAug 21, 2025
      A gas odor during combustion may be due to foreign matter between the control valve and burner. In this case, take apart the gas tubing and remove any foreign matter. It can also be caused by a gas leak, so locate and correct all leaks.

Summary

SAFETY

SPECIFICATIONS

Technical details and dimensions of the heater model BWH10NLMC-2.

QUALIFIED INSTALLING AGENCY

Requirements for qualified personnel to install and service the heater.

PRODUCT FEATURES

Key features like Safety Pilot and Piezo Ignition System.

LOCAL CODES

Guidelines regarding local, state, and national codes for installation.

PREPARING FOR INSTALLATION

UNPACKING

Steps for removing the heater and its packaging.

WATER VAPOR MANAGEMENT

Explanation of water vapor as a byproduct and how to manage it.

AIR FOR COMBUSTION AND VENTILATION

VENTILATION METHODS

Methods for providing ventilation air from inside the building or outdoors.

INSTALLATION

HEATER LOCATION AND CLEARANCES

Guidance on selecting a location and maintaining safe clearances from combustibles.

MOUNTING THE HEATER

Instructions for removing the front panel and securely fastening the heater to the wall.

GAS SELECTION AND CONNECTION

Procedures for selecting the correct gas type and connecting the gas supply.

GAS CONNECTION TESTING

Methods for checking gas connections and pressure testing the system.

OPERATION

PRE-LIGHTING SAFETY CHECKS

Critical safety information and gas leak detection procedures before lighting.

LIGHTING AND SHUTTING DOWN

Step-by-step instructions for lighting the pilot, operating, and turning off the heater.

BURNER INSPECTION AND MAINTENANCE

FLAME PATTERN INSPECTION

How to inspect pilot and burner flame patterns for correct operation.

BURNER AND PILOT CLEANING

Procedures for cleaning the main burner, pilot assembly, and cabinet.

TROUBLESHOOTING

PILOT IGNITION AND BURNER ISSUES

Diagnosing and resolving problems with pilot ignition and burner operation.

GAS LEAKS AND ODORS

Identifying and correcting gas leaks and odors during operation.

OPERATIONAL PROBLEMS AND ANOMALIES

Addressing issues like noises, residue, unwanted odors, and heater shutoffs.

TECHNICAL SERVICE

PARTS AND REPLACEMENT

PARTS LIST

A comprehensive list of available parts for the heater model.

ORDERING REPLACEMENT PARTS

Procedures for ordering parts covered or not covered by the warranty.

ACCESSORIES AND SERVICE HINTS

OPTIONAL ACCESSORIES

Information on purchasing optional heater accessories.

SERVICE HINTS FOR LOW GAS PRESSURE

Troubleshooting tips specifically for issues related to low gas pressure.

WARRANTY INFORMATION

LIMITED WARRANTY DETAILS

Details of the manufacturer's limited warranty terms and coverage.

ReddyHeater BWH10NLMC-2 Specifications

General IconGeneral
ModelBWH10NLMC-2
BrandReddyHeater
Fuel TypePropane
Heater TypePropane
Heat Output10, 000 BTU
BTU Output10, 000 BTU
Propane Tank Connection20 lb propane tank
Safety FeaturesOverheat protection

Related product manuals