VENT-FREE GAS WALL
HEATER
OWNER’S OPERATION AND
INSTALLATION MANUAL
INFRARED MODELS
IWH16NLTD-2
IWH26NLTD-2
WARNING: If the information in this manual is not
followed exactly, a re or explosion may result causing
property damage, personal injury or loss of life.
Do not store or use gasoline or other ammable va-
pors and liquids in the vicinity of this or any other
appliance.
WHAT TO DO IF YOU SMELL GAS
Do not try to light any appliance.
Do not touch any electrical switch; do not use any
phone in your building.
Immediately call your gas supplier from a neighbors
phone. Follow the gas suppliers instructions.
If you cannot reach your gas supplier, call the re
department.
Installation and service must be performed by a quali-
ed installer, service agency or the gas supplier.
WARNING: This appliance is equipped for Natural and
Propane gas. Field conversion is not permitted other than
between natural or propane gases.
IWH26NLTD-2
Shown
Questions, problems, missing parts?
Before returning to your retailer, call our customer service department at
1-800-229-5647, 8:00 am - 4:30 pm EST, Monday through Friday
DRAFT
4-10-17

Questions and Answers

  • J
    jacquelinecarrAug 16, 2025
    What to do if there is spark but no ignition on my ReddyHeater IWH26NLTD-2?
    • M
      Melissa HodgesAug 16, 2025
      If there's a spark but no ignition in your ReddyHeater Heater, first, ensure the gas supply is on and the equipment shutoff valve is open. Make sure the control knob is fully pressed in while pressing the ignitor button. If there's air in the gas lines from installation, keep holding down the control knob and repeat the igniting operation until the air is removed. Check if the ODS/pilot is clogged and clean it, or consider replacing the ODS/pilot assembly. Verify the inlet gas pressure and regulator setting. Ensure the control knob is in the PILOT position. Lastly, if using propane, check for a depleted gas supply.
  • C
    cassandramoyerAug 19, 2025
    Why does the pilot light go out on my ReddyHeater Heater when I release the control knob?
    • C
      Cynthia JonesAug 19, 2025
      If the ODS/pilot light of your ReddyHeater Heater goes out when you release the control knob, make sure the control knob is fully pressed in and held for at least 30 seconds after the pilot lights. Ensure the equipment shutoff valve is fully open. Check the thermocouple connection at the control valve and hand tighten it until snug, then tighten an additional 1/4 turn. Contact your local gas company or clean/replace the ODS/pilot assembly. If the pilot flame isn't touching the thermocouple, allowing it to cool, causing the pilot flame to go out. Consider replacing the thermocouple or control valve if damaged.
  • T
    Tanya SilvaAug 22, 2025
    Why do I smell gas when my ReddyHeater IWH26NLTD-2 is running?
    • C
      cody12Aug 22, 2025
      If you notice a gas odor during combustion in your ReddyHeater Heater, there might be foreign matter between the control valve and burner; disassemble the gas tubing to remove any foreign matter. Also, check for gas leaks and correct them.
  • J
    Jill WalkerAug 25, 2025
    What causes my ReddyHeater Heater to backfire?
    • A
      adrienne85Aug 26, 2025
      If your ReddyHeater Heater burner backfires during combustion, the burner orifice might be clogged or damaged; clean the burner orifice. The burner could also be damaged, or the gas regulator might be damaged, in which case you should replace it.
  • D
    Donna FlemingAug 28, 2025
    What to do if burner doesn't light after pilot on my ReddyHeater Heater?
    • N
      Natalie TaylorAug 28, 2025
      If the burner(s) on your ReddyHeater Heater don't light after the ODS/pilot is lit, it could be due to a clogged burner orifice, so clean the burner orifice. Alternatively, the inlet gas pressure might be too low, in which case you should contact your local gas supplier.
  • R
    Ronald BurtonAug 31, 2025
    How to fix no spark when pressing ignitor on ReddyHeater Heater?
    • C
      Cynthia PearsonAug 31, 2025
      If there is no spark at the ODS/pilot when the ignitor button is pressed on your ReddyHeater Heater, the ignitor electrode might be positioned wrong or broken, so replace the electrode. The ignitor electrode might not be connected to the ignitor cable, so replace the ignitor cable. The ignitor cable could be pinched or wet, so free it from any metal or tubing and keep it dry. The ignitor cable could be broken, so replace it. The piezo ignitor might be bad, so replace it. Finally, the battery might be low, so replace it.
  • P
    porterbrendaSep 3, 2025
    Why is the flame yellow on my ReddyHeater IWH26NLTD-2 Heater?
    • D
      David CarlsonSep 3, 2025
      If you observe a high yellow flame during burner combustion in your ReddyHeater Heater, it could be due to insufficient air. Check the burner for dirt and debris, and clean it if necessary. The gas regulator might be defective, so replace it. The inlet gas pressure could also be too low, so contact your local gas supplier.
  • A
    Andrew BensonSep 6, 2025
    Why is there a delay when igniting my ReddyHeater Heater burner?
    • Z
      Zoe BoyerSep 6, 2025
      If your ReddyHeater Heater experiences delayed ignition of the burner(s), the manifold pressure might be too low, so contact your local gas supplier. Alternatively, the burner orifice could be clogged, so clean the burner.
  • K
    Kristin BaileySep 8, 2025
    What to do if pilot won't light with natural gas on my ReddyHeater IWH26NLTD-2?
    • C
      Cole BrooksSep 8, 2025
      If you are using natural gas and the pilot will not light on your ReddyHeater Heater, it could be that the inlet pressure exceeds 9.5" WC. In this case, bypass the pressure switch.
  • E
    Edwin WrightSep 12, 2025
    Why does my new ReddyHeater IWH26NLTD-2 Heater smell when I first use it?
    • J
      Jose HarrisSep 12, 2025
      If you notice a slight smoke or odor during the initial operation of your ReddyHeater Heater, it is likely due to residues from the manufacturing process. This problem should stop after a few hours of operation.

Summary

Reddy Heater Vent-Free Wall Heater Manual

Safety Warnings and Gas Leak Procedures

Highlights critical safety warnings regarding fire, explosion, and gas leaks.

Critical Safety Warnings and Procedures

General Safety Instructions

Covers essential safety rules for operation, installation, and handling.

Carbon Monoxide Poisoning Danger

Alerts to the severe risk of carbon monoxide poisoning and its symptoms.

Appliance Usage and Supervision

Addresses safe usage, supervision of children, and clearance requirements.

Safety, Agency, and Product Features

Qualified Installing Agency Requirements

Defines the qualifications required for installing and servicing the unit.

Combustion and Ventilation Air Needs

Fresh Air for Fuel-Burning Appliances

Explains the necessity of fresh air for proper combustion and ventilation.

Adequate Indoor Air Volume

Details requirements for indoor combustion air volume based on codes.

Heater Installation Best Practices

Clearances to Combustibles

Specifies minimum safe clearances around the heater.

Installation: Panel Removal & Bracket Mounting

Installation: Marking & Bracket Fastening

Installation: Heater Mounting & Base Feet

Gas Type Selection and Regulator Installation

Propane;LP and Natural Gas Installation Steps

Connecting to Gas Supply Safely

Qualified Technician Gas Connection

Emphasizes the need for a qualified technician for gas connections.

External Regulator for Propane;LP

Explains the requirement for an external regulator for propane/LP gas.

Gas Connection Testing and Leak Checks

Checking Gas Connections for Leaks

Provides instructions for testing gas lines for leaks using soap solution.

Pressure Testing Gas Supply Piping

Outlines procedures for pressure testing the gas supply system.

Pressure Testing and Leak Detection Methods

Testing Gas Supply Piping System

Details pressure testing of the supply piping system for leaks.

Pressure Testing Heater Gas Connections

Covers leak testing of the heater's internal gas connections.

Heater Operation and Pilot Lighting

Safety Before Lighting

Crucial safety steps to follow before attempting to light the pilot.

What to Do If You Smell Gas

Emergency procedures to follow in case of a gas leak detection.

Lighting the Pilot

Step-by-step instructions for manually lighting the pilot light.

Heater Operation, Thermostat, and Shutdown

Electrical Connections and Wiring Safety

Electrical Wiring Safety

Emphasizes safety during electrical wiring and servicing.

Burner Inspection and Flame Pattern Analysis

Heater Care, Maintenance, and Cleaning

Main Burner and Pilot Air Hole Cleaning

Specific steps for cleaning burner holes and pilot air inlets.

Troubleshooting: Gas Leaks and Pilot Problems

Gas Leak Safety Procedures

Reiterates critical safety steps if a gas smell is detected.

Servicing Safety Precautions

Warnings and cautions regarding servicing the heater.

Troubleshooting: Ignition Failures

Troubleshooting: Burner, Gas, and Flame Issues

Burner Backfiring or Yellow Flame

Diagnoses issues like burner backfiring and high yellow flame.

Troubleshooting Other Issues & Technical Service

Product Warranty Terms and Conditions

Limited Warranty Coverage

Details the terms and duration of the product warranty.

ReddyHeater IWH26NLTD-2 Specifications

General IconGeneral
BrandReddyHeater
ModelIWH26NLTD-2
CategoryHeater
LanguageEnglish

Related product manuals