RJS-PREM Series Shallow Well Jet Pump
English
EN
OWNER'S MANUAL
The shallow well jet pump is ideal for the supply of
fresh water to rural homes, farms, and cabins. This
pump is suitable for installations where the vertical
distance from the pump to the water level does not
exceed 25 ft (7.6 m), including draw-down (less at
high altitudes). The intake is 1-1/4” FNPT while the
discharge is 1” FNPT. The pressure gauge port is 1/8”
NPT.
This product is covered by a Limited Warranty for a
period of 3 years from the date of original purchase
by the consumer. For complete warranty information, refer to www.redlionproducts.com
, or call Technical
Support for a printed copy.
Specifications
Model Item Number HP Volts Amps
RJS-50-PREM 602206 1/2 115/ 230 11.8 / 5.9
RJS-75-PREM 602207 3/4 115/ 230 14.4 / 7.2
RJS-100-PREM 602208 1 115/ 230 17.6 / 8.8
Table of Contents
INSTALLATION- - - - - - - - - - - - - - - - - - - - - - - - - -3
Typical Installations- - - - - - - - - - - - - - - - - - -3
Pump Location - - - - - - - - - - - - - - - - - - - - - -4
Physical Installation- - - - - - - - - - - - - - - - - - -4
Electrical Connections - - - - - - - - - - - - - - - - -5
OPERATION- - - - - - - - - - - - - - - - - - - - - - - - - - - -6
Priming with an In-line Check Valve - - - - - - - -6
Priming with a Foot Valve- - - - - - - - - - - - - - -6
MAINTENANCE - - - - - - - - - - - - - - - - - - - - - - - - -7
Periodic Maintenance- - - - - - - - - - - - - - - - - -7
Draining - - - - - - - - - - - - - - - - - - - - - - - - - -7
Replacing Mechanical Seals- - - - - - - - - - - - - -8
Troubleshooting - - - - - - - - - - - - - - - - - - - - -9
Replacement Parts - - - - - - - - - - - - - - - - - - -10

Questions and Answers

  • L
    Lisa KimJul 29, 2025
    What to do if my Redlion RJS-PREM Water Pump fails to deliver water?
    • V
      vdavisJul 29, 2025
      If your Redlion Water Pump isn't delivering water, several factors could be at play. First, ensure the pump is completely primed. If the suction lift is too high, relocate the pump closer to the water source. Also, check the foot valve to ensure it is submerged and not obstructed by mud or other debris; clean or replace it if necessary.
  • C
    Cathy StephensAug 3, 2025
    How to troubleshoot a Redlion Water Pump motor that will not start?
    • S
      stephanie57Aug 3, 2025
      If the motor of your Redlion Water Pump won't start, begin by checking all electrical connections to ensure they are secure and inspect the breaker and fuses. Also, make sure the pump pressure switch is closed.
  • A
    Amanda TownsendAug 10, 2025
    Why does my Redlion RJS-PREM keep losing prime?
    • R
      rbarajasAug 10, 2025
      If your Redlion Water Pump loses prime, check for air leaks in the suction line and repair or replace as needed. If the well draws down too far, move the pump closer to the water source. Also, inspect the foot valve and clean or replace it if faulty.
  • P
    Patricia PowellAug 15, 2025
    Why does my Redlion RJS-PREM start and stop too often?
    • J
      Joshua RossAug 15, 2025
      If your Redlion Water Pump starts and stops too often, it could be due to a faulty air volume control, which would require replacement. Alternatively, there might be air leaks in the tank above the water level; check the fittings and consider replacing the tank. Another cause can be incorrect setting on the pressure switch.
  • D
    dianemortonAug 21, 2025
    What to do if my Redlion RJS-PREM delivers water, but not at rated capacity?
    • A
      Andrew KeithAug 21, 2025
      If your Redlion Water Pump delivers water but not at its rated capacity, there are several potential causes. Check for leaks in the suction or discharge lines, and clean or replace them as needed. Inspect the foot valve, suction line, impeller, or nozzle for partial blockages and clean as necessary. If the suction lift is greater than recommended, relocate the pump closer to the water source. Ensure the proper gauge wire has been used and verify that the motor is wired for the correct voltage, matching the voltage at the power source.

Summary

Owners Manual and Product Overview

Specifications

Details pump model, item number, HP, voltage, and current ratings for different models.

Safety Instructions and Warnings

General Safety Instructions and Hazards

Covers hazards like explosion, fire, electric shock, high voltage, and bodily injury.

Installation Guide

Typical Installation Diagrams

Illustrates common plumbing system arrangements for shallow well jet pumps.

Pump Location Recommendations

Guidance on selecting a clean, dry, ventilated location for the pump.

Physical Installation Procedures

Details on connecting plumbing, pressure relief valves, and gauges.

Electrical Connections and Voltage Change

Instructions for wiring, changing voltage, and ensuring proper grounding.

Operating the Pump

Priming with In-line Check Valve

Step-by-step guide to prime the pump using an in-line check valve.

Priming with Foot Valve

Step-by-step guide to prime the pump using a foot valve.

Maintenance Procedures

Periodic Maintenance Checks

Tasks include checking foundation, leaks, performance, and cleaning.

Draining the System

Instructions for draining the pump and system for cold weather or maintenance.

Replacing Mechanical Seals

Detailed disassembly and reassembly steps for replacing pump seals.

Troubleshooting Guide

Common Problems and Solutions

Lists common issues like motor not starting, pump losing prime, and capacity problems.

Replacement Parts List

Parts Identification and Ordering

Diagram and list of parts with corresponding item numbers and order numbers.

Redlion RJS-PREM Series Specifications

General IconGeneral
BrandRedlion
ModelRJS-PREM Series
CategoryWater Pump
LanguageEnglish

Related product manuals