Instruction Manual
14
Hold function
A special function on the REFSCALE-S allows you to freeze the
value. This function can be used, for example, when filling or
emptying the system when in case the gas cylinder fis empty or
full.
The function is activated by briefly pressing and the symbol
appears on the display.
To deactivate the function, press again .
Alarm
With the REFSCALE-S a programmable alarm value can be set.
The alarm will sound when the required value (either positive for
increasing weight, or negative for decreasing weight) is reached.
After 90% of the programmed value, an approaching alarm
brings to your attention, with an alternating tone, that the
required amount is nearly reached. While reaching 100%, a
continuous tone sounds.
1. press , enter the menu
2. press , navigate to alarm
3. press , confirm
4. press , «SET» is displayed
5. press , confirm «SET»
6. press , Define the value at which the alarm should be
triggered
7. press , confirm value