IQ-LOGGER™
This easy-to-use core logging solution provides
fast, accurate structural measurements
Q U I C K R E F E R E N C E G U I D E
REFLEX IQ-LOGGER Software v1.2
Inside
1. Installation
2. Set Up
3. Initialisation
4. Logging
5. Verification
Compatible
The information contained in this document is believed to be accurate at the time of printing; however, Imdex Limited, its subsidiaries, agents, distributors or resellers assume no responsibility
or liability for the accuracy or completeness of, or consequences arising from, such information and the use of such information. Changes, typos, and technical inaccuracies will be corrected in
subsequent publications. This publication is subject to change without notice.
Determination of the suitability of any information or product for use contemplated by any user, and the manner of that use is the sole responsibility of the user.
Copyright © 2017 Imdex Limited.
Question and Answer IconNeed help?

Do you have a question about the Reflex IQ-LOGGER and is the answer not in the manual?

Reflex IQ-LOGGER Specifications

General IconGeneral
BrandReflex
ModelIQ-LOGGER
CategoryData Loggers
LanguageEnglish

Summary

IQ-LOGGER™ SET UP

Charge Battery

Connect the device via USB cable for charging. Orange light indicates status.

Pair IQ-LOGGER™ to Computer

Turn on the IQ-LOGGER™ and enable Bluetooth on the computer for pairing.

Launch Software

Launch the REFLEX IQ-LOGGER™ application and press the Sync button.

Add Project

Create a new project within the software, specifying details like name and units.

Add Drillhole

Add a drillhole entry, including name, type, planned depth, and azimuths.

Configure Drillhole

Set up drillhole configuration, logger name, core alignment, and feature lists.

IQ-LOGGER™ INITIALISE

Power On Device

Press and hold side buttons until green and blue lights turn on, red light flashes.

Stabilise Gyroscopes

Wave the device in a figure-eight pattern five times, then place on a flat surface.

Align Device

Place the device on the drillhole orientation line, point downhole, and press a side button.

IQ-LOGGER™ LOGGING

Set Depth and Structure Type

Define the starting depth and select the structural feature from the dropdown list.

Move Device Downhole

Roll the device along the core on the orientation line, monitoring depth increase.

Align with First Structure

Position the device so the alignment marker is inline with the first structure.

Measure First Structure

Lift the device, align the laser with the structure, and click the front button to record.

Move to Second Structure

Slide device to the next structure, align with orientation line, and click side button.

Select Structure Type

Change the structure type setting on the device using the Back button.

Measure Next Structure

Align laser with structure, click front button to record measurement.

Take Measurements for All Structures

Repeat logging steps for all relevant structures of interest.

Sync to Upload

Use the Sync function to upload collected data to the Hub.

Turn Off Device

Press and hold side buttons until all indicator lights extinguish to turn off.

IQ-LOGGER™ VERIFICATION

Verify Data