Installation and Operating Manual
REFUsol 08K ... 23K
English
REFU Elektronik GmbH No. 982030, Version 02 2018-06

Table of Contents

Questions and Answers

  • P
    Patricia GlennSep 2, 2025
    What to do if REFU Inverter showing overtemperature LT 1?
    • L
      Lisa GarciaSep 2, 2025
      If your REFU Inverter displays an overtemperature LT 1 error, it indicates a cooler overtemperature (right). Check the temperature of the direct surroundings and reduce it as required.
  • M
    Melanie MorenoAug 31, 2025
    Why REFU Inverter shows external cut-off error?
    • C
      Carrie HancockAug 31, 2025
      If your REFU Inverter detects an external cut-off, it means external monitoring has triggered a disconnection. Verify the external cut-off signal. Possible causes include wire breakage or a wrong sensor selection. Refer to the manual for the correct settings.
  • B
    Benjamin BassAug 29, 2025
    How to troubleshoot PM isolation RCD SR error on REFU Inverter?
    • M
      Michelle SchneiderAug 29, 2025
      If your REFU Inverter shows a PM isolation RCD SR error, it means the measured value of the residual currents are over the limits. Check system isolation. If you consider the system isolation to be in order, contact Service.
  • O
    Olivia BurtonAug 28, 2025
    What causes grid frequency LT error in REFU REFUsol 20K?
    • T
      tpaulAug 28, 2025
      If your REFU Inverter displays a grid frequency LT error, it means the power section has detected under/overfrequency. Check the frequency of the phases. If you consider the frequencies to be in order, contact the Service.
  • G
    Gary LeeAug 27, 2025
    Why REFU REFUsol 20K Inverter showing overvoltage 2?
    • K
      Kathleen DiazAug 27, 2025
      If your REFU Inverter detects overvoltage 2, the phase voltage has exceeded the limit value of the voltage average monitor for too long. Monitor line voltages and analyze the grid. If the line voltages appear to be in order, contact Service.
  • J
    Jessica NelsonAug 25, 2025
    What to do if REFU REFUsol 20K Inverter showing overfrequency?
    • S
      Steven MillerAug 25, 2025
      If your REFU Inverter is detecting an overfrequency, it means the grid frequency has exceeded the limit value. Check the frequency of the phases. If you believe the frequencies are normal, contact Service.
  • D
    Douglas WalkerAug 22, 2025
    How to fix grid overvoltage on REFU Inverter?
    • P
      Patrick FrancisAug 22, 2025
      If your REFU Inverter displays a grid overvoltage error, it means a phase overvoltage (AC) has been detected. Check the phase voltages using a true RMS measurement device. If the phase voltages appear normal, contact Service.

Summary

Safety Information

Qualification of Personnel

Specifies the target audience and required qualifications for operating the inverter safely.

Dangers Arising from Misuse

Highlights potential dangers from improper handling, installation, or use of the inverter.

Protection Against Electrical Parts

Details safety measures to prevent contact with live electrical parts.

Protection Against Hot Parts

Warns about potential burns from hot surfaces on the inverter housing.

Protection During Handling and Assembly

Provides safety instructions for handling and assembling the inverter to prevent injuries.

Description of the Device

Installation

Assembly Site Requirements

Specifies the conditions and restrictions for the inverter's installation location.

Commissioning

Turning on the Device

Provides steps for powering up the inverter and initial checks.

Setting Country Code and Menu Language

Guides through initial setup of country code and language for grid parameters.

Device Start Sequence

Details the sequence of events during inverter startup and self-test.

Configuration

Changing the Menu Language

Step-by-step guide to change the inverter's display language.

Limitation of the Power Output

Instructions on how to limit the inverter's power output.

REFUset - PC Configuration Tool

Explains the use of REFUset software for firmware updates and parameter settings.

Troubleshooting

Self-Test - Error Message

Explains the self-test routine and handling of detected errors.

Transient Failures

Describes transient offline states and automatic fault acknowledgement.

Faults and Error Indicators

Details types of faults, their indicators, and the fault memory.

Options

Maintenance

Decommissioning

Technical Data

REFU REFUsol 20K Specifications

General IconGeneral
Rated Power20 kW
AC nominal voltage400 V
AC voltage range310 V - 480 V
Nominal grid frequency50 Hz / 60 Hz
Max. DC voltage1000 V
Number of MPP trackers2
Max. input current per MPP tracker33 A
Weight45 kg
Frequency50 Hz / 60 Hz
TopologyTransformerless
Operating Temperature Range-25°C to +60°C
Protection RatingIP65
Max. apparent AC power20000 VA
Max. DC power21000 W
Input Voltage Range200 V - 1000 V
Maximum Efficiency98.2%