Gi33LE Gas Insert | 1
Fireplace Dimensions
The minimum replace clearances and dimensions for the Regency
gas insert are shown in the following diagrams:
Regency
®
Gi33LE Gas Insert
MODEL Gi33LE-NG Gi33LE-LP
Fuel Type Natural Gas Propane
Minimum Supply Pressure
5” W.C.
(1.25 kPa)
11” W.C.
(2.74 kPa)
Manifold Pressure - High
3.8” W.C.
(0.94 kPa)
10.5” W.C.
(2.62 kPa)
Manifold Pressure - Low
1.1” W.C.
(0.27 kPa)
2.9” W.C.
(0.72 kPa)
Orice Size -Altitude 0-4500 ft #33 DMS #50 DMS
Minimum Input (0-4500 ft.)
20,500 Btu/h
(6.01 kW)
20,000 Btu/h
(5.86 kW)
Maximum Input (0-4500 ft.)
38,500 Btu/h
(11.28 kW)
36,500 Btu/h
(10.7 kW)
Vent Sizing 3”x 4” Co-linear 3”x 4” Co-linear
CSA P.4.1 Fireplace
Eciency (FE)
64.30% 64.32%
B
ES T
D
Q
A
G
R
H
F
I
J K
U
P
O
N M L
C
Leer Descripon Dimensions
(inches)
Dimensions
(mm)
A Width 33-7/8" 860 mm
B Outerbox Width 32-1/2" 826 mm
C Outerbox Height 23-5/8" 601 mm
D Outerbox Depth 19-1/4" 489 mm
E Outerbox Rear Width 21-7/8" 555 mm
F Front to Top Taper 9-5/8" 245 mm
G Front to Side Taper 4-1/2" 114 mm
H Rear to Side Taper 14-13/16" 377 mm
I Gas Inlet Height 1-7/16" 36 mm
J Gas Inlet Rear Depth 5-15/16" 150 mm
K Gas Inlet Front Depth 13-5/16" 338 mm
L Electrical Access Height 1-5/16" 34 mm
M Electrical Access Rear Depth 8-7/16" 215 mm
N Electrical Access Front Depth 10-3/4" 274 mm
O Glass Viewing Area Width 28-11/16" 729 mm
P Glass Viewing Area Height 18-1/8" 460 mm
Q Front to Intake 16-7/16" 417 mm
R Front to Exhaust 15-1/2" 394 mm
S Intake Diameter 3" 76 mm
T Exhaust Diameter 4" 102 mm
U Depth 18" 457 mm
B
ES T
D
Q
A
G
R
H
F
I
J K
U
P
O
N M L
C
B
ES T
D
Q
A
G
R
H
F
I
J K
U
P
O
N M L
C
B
ES T
D
Q
A
G
R
H
F
I
J K
U
P
O
N M L
C