CLASSIC C34-3 Direct Vent Freestanding Gas Stove
9
INSTALLATION
IMPORTANT MESSAGE
SAVE THESE
INSTRUCTIONS
The CLASSIC Direct Vent Freestanding Gas
Stove must be installed in accordance with these
instructions. Carefully read all the instructions in
this manual rst. Consult the building authority
having jurisdiction to determine the need for a
permit prior to starting the installation.
- WARNING -
Failure to follow the instructions
could cause a malfunction of the
heater which could result in death,
serious bodily injury, and/or prop-
erty damage. Failure to follow these
instructions may also void your re
insurance and/or warranty.
Note: These instructions take precedence
over Simpson Dura-Vent instructions
SPECIFICATIONS
Fuels: C34-NG is approved for use with
natural gas. C34-LP is approved for
use with lique ed petroleum gases
(propane).
Electrical: 120V. A.C. system.
Optional circulation fan: Two speed,
125/75 CFM.
Log Sets: Ceramic bre, 4 per set.
Vent System: Coaxial (6 5/8" outer/ 4" inner
liner) rigid ue and termination cap.
GENERAL SAFETY
INFORMATION
1) The appliance installation must conform with
local codes or, in the absence of local codes,
with the current Canadian or National Electrical
Codes, CAN1-B149 or ANSI Z223.1 Installation
Codes.
2) The appliance when installed, must be electri-
cally grounded in accordance with local codes,
or in the absence of local codes with the current
National Electrical Code, ANSI/NFPA 70 or CSA
C22.1 Canadian Electrical Code.
3) The appliance should be inspected for shipping
damage before use and serviced annually by
a professional service person. More frequent
cleaning may be required due to excessive lint
from carpeting, bedding material, etc. It is impera-
tive that control compartments, and circulating
air passageways of the appliance be kept clean.
4) See general construction and assembly in-
structions. The appliance and vent should be
enclosed when installed in or passing through
a living area.
5) This appliance must be connected to the speci-
ed vent and termination cap to the outside of
the building envelope.
6) Never vent to another room or inside a build-
ing. Make sure that the vent is tted as per the
instructions starting in "Venting Introduction"
section.
7) Inspect the venting system annually for blockage
and any signs of deterioration.
8) Venting terminals shall not be recessed into a
wall or siding.
9) Any safety glass removed for servicing must be
replaced prior to operating the appliance.
10) To prevent injury, do not allow anyone who is
unfamiliar with the operation to use the replace.
SHOULD OVERHEATING OC-
CUR, OR THE GAS SUPPLY FAIL
TO SHUT OFF, SHUT OFF THE
MANUAL GAS VALVE TO THE
APPLIANCE BEFORE SHUT-
TING OFF THE ELECTRICAL
SUPPLY.
- WARNING -
Risk of re or electric shock. Only
quali ed service personnel shall be
used to install and provide mainte-
nance of this appliance.
1) Provide adequate clearances for servicing,
proper operation and around the air openings
into the combustion chamber.
2) The appliance may be installed on a at, solid,
continuous surface (e.g. wood, metal, concrete).
This may be the oor, or it can be raised up on
a platform to enhance its visual impact. If the
appliance is going to be installed on carpeting,
see clearances to combustibles in "Clearances
to Combustibles" section.
The CLASSIC Direct Vent Freestanding Gas
Stove can be installed in a wide variety of ways
and will t nearly any room layout. It may be
installed in a recessed position, framed out into
the room, or across a corner. This appliance is
Listed for Alcove installations, maintain minimum
Alcove clearances as follows, minimum ceiling
height of 65-11/16", minimum width of 48" and
a maximum depth of 36".
3) The CLASSIC Direct Vent Freestanding Gas
Stove is approved for alcove installations, which
meet the clearances listed in "Clearances to
Combustibles" section. This unit can be installed
in a bedroom, when installed with a millivolt ther-
mostat. This unit is approved for manufactured
home installations, see "Venting Arrangements"
section for the required vent arrangements. If
installed into a manufactured or mobile home
the unit must be bolted down to the oor.
4) We recommend that you plan your installation on
paper using exact measurements for clearances
and oor protection before actually installing this
appliance. Have a quali ed building inspector
review your plans before installation.
Emissions from burning wood or gas could
contain chemicals known to the State of Cali-
fornia to cause cancer, birth defects or other
reproductive harm.