improved. Check the label on the unit and if
correct one.
Part #: 918-176f
Size: 3"Hx20-1/2"W(leat100%)
Colour: Blackongrey,exceptforwhatisindicatedasbeingprintedredongrey.
June20/07:updatedlogoasperSCCrequirements.
Mar.1/10:UpdatedLogo
Apr.7/11:Updateddateofmanufacture/added5.5"liner
Oct.3/13RevD-updatedyrofmanufacture
May5/15:Rev.E-addedFrench
May2/16:Rev.F-updatedyrofmanufacture2017-2021
SIGNATURE
JanFebMarAprMayJune
JulyAugSeptOctNovDec
DATE OF
MANUFACTURE
INSTALL AND USE ONLY IN ACCORDANCE WITH THE MANUFACTURER'S INSTALLATION AND OPERATING INSTRUCTIONS. INSTALL AND USE ONLY IN MASONRY
FIREPLACE OR FACTORY BUILT FIREPLACE. CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN
YOUR AREA.
INSTALLER ET UTILISER SELONS LES INSTRUCTIONS DU FABRICANT. INSTALLER ET UTILISER DANS UN FOYER DE MACONNERIE OU PRÉFABRIQUÉ.
APPELER VOTRE INSPECTEUR DE BÂTIMENT OU LE DÉPARTMENT D’INCENDIE LOCAL POUR LES CODES LOCAUX ET POUR INSPECTÉE
VOTRE INSTALLATION ET FOYER.
LISTED FACTORY BUILT FIREPLACE INSERT
CERTIFIED FOR USE IN CANADA AND U.S.A.
MODEL: I2400M
TESTED TO: ULC-S628-93 / UL-1482 / UL-737
REPORT NO.: 219-S-03-2
THE I2400M MEETS UL-737 STANDARD FOR FIREPLACE STOVES WHEN A FIRESCREEN IS PROVIDED.
DO NOT REMOVE THIS LABEL
246
MINIMUM CLEARANCES TO
COMBUSTIBLE MATERIALS (MEASURED
FROM INSERT BODY)
ADJACENT
SIDEWALL A) 11 in / 280 mm
MANTLE B) 20 in / 508 mm
TOP FACING C) 12 in / 305 mm
SIDE FACING D) 8 in / 200 mm
COMPONENTS REQUIRED FOR INSTALLATION: 5.5" (140mm) or 6" (152mm) STAINLESS STEEL LINER.
OPTIONAL COMPONENT: FAN (142-917), ELECTRICAL RATING: VOLTS 115, 60 HZ, 0.6 AMPS, SCREEN DOOR (846-102)
DANGER: RISK OF ELECTRIC SHOCK. DISCONNECT POWER BEFORE SERVICING UNIT. DO NOT ROUTE POWER CORD UNDER OR IN
FRONT OF APPLIANCE. DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVICING ANOTHER APPLIANCE. DO NOT REMOVE BRICKS
OR MORTAR IN MASONRY FIREPLACE. FOR USE WITH SOLID WOOD FUEL ONLY. DO NOT USE GRATE OR ELEVATE FIRE. BUILD WOOD
FIRE DIRECTLY ON HEARTH. RISK OF SMOKE AND FLAME SPILLAGE, OPERATE ONLY WITH DOORS FULLY OPEN OR FULLY CLOSED. IF
INSTALLED IN A MOBILE HOME OPERATE ONLY WITH DOORS FULLY CLOSED - OPEN FEED DOOR TO FEED FIRE ONLY. WHEN OPER-
ATED WITH DOORS OPEN THE MANUFACTURER SUPPLIED SCREEN MUST BE USED. REPLACE GLASS ONLY WITH CERAMIC GLASS
(5MM). INSPECT AND CLEAN CHIMNEY FREQUENTLY. UNDER CERTAIN CONDITIONS OF USE CREOSOTE BUILDUP MAY OCCUR RAP-
IDLY. DO NOT OVERFIRE, IF INSERT GLOWS YOU ARE OVER-FIRING.
PIÈCES NÉCESSAIRES POUR INSTALLATION :5.5" (140MM) OR 6" (152MM) CONDUITS EN ACIER INOXYDABLE.
COMPOSANT FACULTATIF : VENTILATEUR (142-917); CARACTÉRISTIQUES ÉLECTRIQUES NOMINALES : 115 VOLTS, 60 HZ, 0,6 A, PARE-
ÉTINCELLES (846-102)
DANGER : RISQUE DE CHOC ÉLECTRIQUE. DÉBRANCHER L’APPAREIL AVANT TOUTE RÉPARATION. NE PAS FAIRE PASSER LE FIL
ÉLECTRIQUE DEVANT L’APPAREIL NI EN DESSOUS. NE PAS RELIER CET APPAREIL À UNE CHEMINÉE DESTINÉE À L’ÉVACUATION D’UN
AUTRE APPAREIL. NE PAS ENLEVER DE BRIQUES NI DE MORTIER D’UNE CHEMINÉE DE MAÇONNERIE. N’UTILISER QUE DU COMBUS-
TIBLE DE BOIS SOLIDE. NE PAS SURÉLEVER LES BÛCHES NI LES PLACER SUR DES GRILLES, MAIS LES DÉPOSER DIRECTEMENT
SUR L’ÂTRE. RISQUE DE DÉGAGEMENT DE FUMÉE OU DE FLAMMES : TOUJOURS GARDER LES PORTES COMPLÈTEMENT OUVERTES
OU FERMÉES LORSQUE L’APPAREIL FONCTIONNE. DANS UNE MAISON MOBILE, TOUJOURS GARDER LES PORTES BIEN FERMÉES
LORSQUE L’APPAREIL FONCTIONNE. OUVRIR LA PORTE UNIQUEMENT POUR ALIMENTER LE FEU. SI LES PORTES DU POÊLE RESTENT
OUVERTES, TOUJOURS UTILISER LE PARE-ÉTINCELLES FOURNI PAR LE FABRICANT. REMPLACER LA VITRE UNIQUEMENT PAR UNE
VITRE EN VITROCÉRAMIQUE (5 MM). INSPECTER ET NETTOYER FRÉQUEMMENT LA CHEMINÉE. SELON LE TYPE D’USAGE, LE CRÉO-
SOTE PEUT S’ACCUMULER RAPIDEMENT. NE PAS SURCHAUFFER; SI L’ENCASTRABLE SE MET À ROUGIR, IL SURCHAUFFE.
CAUTION / ATTENTION
HOT WHILE IN OPERATION DO NOT TOUCH. KEEP CHILDREN,
CLOTHING AND FURNITURE AWAY. CONTACT MAY CAUSE
SKIN BURNS. READ ABOVE INSTRUCTIONS.
CHAUD LORS DE FONCTIONNEMENT.
NE PAS TOUCHER. GARDEZ LES ENFANTS, VÊTEMENTS ET
MEUBLES AU LOIN. UN CONTACT AVEC LE PEAU PEUT
OCCASIONER DES BRULURES.BRÛLURES CUTANÉES. LIRE
CETTE ÉTIQUETTE.
INSTALL ONLY ON A NON-COMBUSTIBLE HEARTH RAISED (F) 0.5IN / 13MM ABOVE AN ADJACENT COMBUSTIBLE FLOOR. COMBUSTIBLE FLOOR MUST BE PROTECTED
BY NON-COMBUSTIBLE MATERIAL EXTENDING (E) 18 IN / 457 MM TO FRONT AND (G) 8 IN / 205 MM TO SIDES FROM FUEL DOOR. 0.5" FLOOR PROTECTION NEEDS
TO BE WITH k=0.84.
INSTALLER SUR UN ÂTRE DE MATÉRIAU NOM COMBUSTIBLE SURÉLEVÉ (F) 0,5 POUCES / 13MM-DESSUS DU PLANCHER COMBUSTIBLE ADJACENT.
LE PLANCHER COMBUSTIBLE DOIT ÊTRE PROTÉGÉ PAR LE MATÉRIAU NOM COMBUSTIBLE QUI ÉTENDRE (E) 18 IN / 457MM À L’AVANT ET (G) 8 PO / 205 MM DE
CHAQUE CÔTÉ DE LA PORTE. LE REVÊTEMENT DE PLANCHER DOIT AVOIR UNE ÉPAISSEUR DE 0,5 PO ET UN COEFFICIENT K DE 0,84.
MADE IN CANADA 918-176e
(DuplicateSerial#)246
ManufacturedBy
:
FIREPLACE PRODUCTS INTERNATIONAL LTD.
6988 VENTURE ST., DELTA, BC V4G 1H4
2017
2018
2019
2020
2021
918-176f