EasyManua.ls Logo

Regency Ei29 - Control System Technical Data

Regency Ei29
60 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
15
Installer's Information
A 120V 12.5A 60Hz supply is required.
Rated power consumption:
Ei29: 1400 Watts
Optional (Hardwire only) 240V 2 phase 15A 60Hz supply can be utilized.
Rated power consumption:
Ei29: 2800 Watts
THIS APPLIANCE MUST BE GROUNDED.
IMPORTANT: A 15 AMP, 60Hz circuit is required for 120 VAC installation. Additional appliances on the same circuit may exceed the
current rating of that circuit. A dedicated circuit is not required, but is preferred to prevent circuit breaker trips or fuse failure. Optional
240 VAC 2 phase may only be hardwired. FAILURE TO ADEQUITLY POWER APPLIANCE AT REQUIRED VOLTAGE AND AMPERAGE WILL
VOID YOUR WARRANTY.
A 3 prong plug with 93.3" (2.37m) power lead and a separate hard wiring kit are supplied.
2 x Remote control handset battery (AAA).
Note: The wiring from the appliance to the breaker must be supplied by a qualified electrician. This is not supplied with the appliance.
MAIN CONTROL BOARD
REMOTE RECEIVER
BOARD
REMOTE CONTROL
Hardware RC01-070A01 RF290B V1.2 RF290A-TX-V1.3
Software V0 V2.4.1
Frequency ASK/OOK 433.92MHZ
Maximum Transmit Power 10mW
CONTROL SYSTEM TECHNICAL DATA
ELECTRICITY SUPPLY