FPI FIREPLACE PRODUCTS INTERNATIONAL LTD. 6988 Venture St., Delta, BC Canada, V4G 1H4
918-063a
MODELS: P33R-NG2 Natural Gas P33R-LP2 Propane
P33R Zero Clearance Rear Direct Vent
Gas Fireplace
04/26/04
Owners &
Installation Manual
WARNING:
If the information in these instructions are not followed exactly
,
a fire or explosion may result causing property damage
,
personal injury or loss of life.
FOR YOUR SAFETY
Do not store or use gasoline or other flammable vapors an
d
liquids in the vicinity of this or any other appliance.
Installation and service must be performed by a qualifie
d
installer, service agency or the gas supplier.
FOR YOUR SAFETY
What to do if you smell gas:
Do not try to light any appliance
Do not touch any electrical switch
:
do not use any phone in you
r
building.
Immediately call your gas supplie
r
from a neighbour's phone. Follow
the gas supplier's instructions.
If you cannot reach your ga
s
supplier, call the fire department.
Tested by:
Installer: Please complete the details on the back cover
and leave this manual with the homeowner.
Homeowner: Please keep these instructions for future reference.
www.regency-fire.com

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Regency P33R-NG2 and is the answer not in the manual?

Summary

Safety Label

Installation

Important: Save These Instructions

Essential safety and installation instructions must be read and saved before proceeding.

Before You Start

General preparation and safety considerations before beginning the installation process.

General Safety Information

Key safety guidelines and precautions for appliance installation and operation.

Manufactured Mobile Home Additional Requirements

Special requirements for installing the appliance in manufactured or mobile homes.

Installation Checklist

A step-by-step checklist to ensure all installation requirements are met.

Unit Dimensions

Detailed measurements and physical specifications of the fireplace unit.

Locating Your Gas Stove

Guidelines for choosing an appropriate and safe location for the gas stove.

Duct System Option

Information about the optional HeatWave Air Duct Kit for heat dispersal.

Clearances

Specifies minimum required clearances to combustible materials for safety.

Combustible Mantels

Detailed mantel clearances from the unit for combustible materials.

Mantel Leg Clearances

Clearances required for combustible mantel legs adjacent to the unit.

Framing and Finishing

Instructions for framing the enclosure and finishing the area around the unit.

Unit Assembly Prior to Installation

Steps for assembling specific unit components before final installation.

Exterior Vent Termination Locations

Guidelines for safe and code-compliant exterior vent terminal placement.

Venting Introduction

Overview of the balanced flue technology and approved venting systems.

Regency Direct Vent System (Flex) Horizontal Terminations Only

Installation details for the Regency Direct Vent Flex system for horizontal runs.

Installation Procedures for Regency Direct Vent System (Flex)

Step-by-step guide for installing the Regency Direct Vent System (Flex).

Simpson Dura-Vent Venting

Information on using the Simpson Dura-Vent Direct Vent GS system.

Simpson Dura-Vent Venting Components List

List of available Simpson Dura-Vent components for installation.

Venting Arrangements - Horizontal Terminations

Diagrams and guidelines for horizontal venting configurations.

Venting Arrangements - Vertical Terminations

Diagrams and guidelines for vertical venting configurations.

Vertical Termination with Co-Linear Flex System

Installation of a co-linear flex system for vertical termination.

Horizontal Installations

Detailed procedures for horizontal vent installations.

Vertical Termination

Detailed procedures for vertical vent installations.

Gas Line Installation

Instructions for connecting the gas supply line to the appliance.

Pilot Adjustment

Guidance on adjusting the pilot flame for correct operation.

High Elevation

Considerations for operating the unit at high altitudes.

Gas Pipe Pressure Testing

Procedure for testing gas pipe pressure to ensure safety.

Conversion Kit from Natural Gas to Propane

Steps for converting the appliance from natural gas to propane.

Optional Brick Panels

Instructions for installing optional decorative brick panels.

Log Set Installation

Proper installation procedure for the ceramic log set.

Standard Flush Door

Instructions for installing the standard flush door assembly.

Optional Flush Trim

How to install the optional trim for the flush door.

Flush Louvers

Installation of flush mount louvers for the fireplace.

Double Screen Door

Instructions for installing the optional double screen door.

Optional Bay Door

How to install the optional bay door assembly.

Bay Louvers

Installation of bay mount louvers for the fireplace.

Optional Wall Thermostat

Wiring and installation of an optional wall thermostat.

Optional Remote Control

Installation and setup of the optional remote control system.

Optional Wall Switch

Wiring and installation of an optional wall switch.

Wiring Diagram

Electrical wiring diagram for the fireplace and optional components.

Installing the Optional Fan

Detailed instructions for installing the optional fan assembly.

Operating Instructions

Copy of the Lighting Plate Instructions

Safety precautions and basic lighting instructions from the appliance label.

Lighting Instructions

Step-by-step guide for lighting the pilot and main burner.

To Turn Off Gas Appliance

Procedure for safely turning off the gas appliance.

Shutdown Procedure

Steps to properly shut down the appliance, including pilot and main burner.

First Fire

Guidance for the initial start-up and curing process of the fireplace.

Aeration Adjustment

How to adjust the air shutter for optimal flame and performance.

Maintenance

Normal Operating Sounds of Gas Appliances

Describes common and normal sounds produced by the gas appliance.

Maintenance Instructions

General guidelines for cleaning and maintaining the appliance.

General Vent Maintenance

Procedures for inspecting and maintaining the venting system.

Gold-Plated or Brass Louvers

Care instructions for gold-plated or brass louvers.

Gold-Plated or Brass Trim

Care instructions for gold-plated or brass trim.

Log Replacement

Procedure and precautions for replacing the ceramic log set.

Thermopile;Thermocouple

Instructions for replacing the thermopile or thermocouple.

Glass Gasket

Information on replacing the glass gasket for the flush and bay fronts.

Flush Glass Replacement

Steps for replacing the glass on the flush door.

Bay Glass Replacement

Steps for replacing the glass on the bay door.

Removing Valve

Detailed steps for safely removing the gas control valve.

Installing Valve

Detailed steps for safely installing the gas control valve.

Parts List

Main Assembly

List of parts for the main fireplace assembly.

Burner & Log Assembly

List of parts for the burner and log assembly.

Flush Front & Louvers

List of parts for the flush front and louvers.

Bay Front & Louvers

List of parts for the bay front and louvers.

Warranty

The Warranty: Lifetime

Details on the lifetime warranty coverage for specific components.

Conditions

Terms and conditions for warranty validation and service.

Exclusions

Components and conditions not covered by the limited lifetime warranty.

Regency P33R-NG2 Specifications

General IconGeneral
Fuel TypeNatural Gas
Efficiency73%
Ignition SystemElectronic Ignition
Vent TypeDirect Vent
Log Set IncludedYes
BTU Output22, 000 BTU
Heating AreaUp to 1, 000 sq ft
Heat Output22, 000 BTU