87
Active parameter set (for explanation, see Section 11.3).
Appears only when the external sensor Sn2 is not connec-
ted.
Address of the RT 45 unit with interface. Appears only when
the unit is connected to the computer.
Setting ranges SPI 32 to 99.
Mannesmann Demag CAN 13 to 17.
Profibus DP 3 to 99.
7.2 Function Level “SEt Fun”
For programming functions (SEt Functions). This level is
reached from “SEt SEL” by pressing the “∆” and “∇” keys
simultaneous.
The desired setting can be reached by pressing the “Up” or
“Down” keys.
To move backwards: press the “P” key for a maximum of
2 s.
To return to the operating level with display of the set and
actual values from any desired display, press the “P” key for
3 s.
Temperature display in °C or °F.
Pump run-out temperature. Before switching the unit off
(Off) or to suction mode (Suction), the fluid is cooled to this
temperature. 0=function off: leak-stop and suction not pos-
sible.
P140 and P140S with direct cooling: PtE = 0. Provides
automatic pressure relief for 30 seconds after the unit is
switched off via the OFF button.
Suction or drainage time by compressed air time in s.
Display if option present.
Cycle time for heating in s.
Cycle time for cooling in s.
Max. adjustable set value and electronic safety thermostat.
Circulating fluid: yES = Water, no = thermal oil.
P
PAr 5
1 to 11
P
3 s
SEt SEL
P
dEG CEL
CEL/FAr
P
PtE 0
0 to 80 (°C)
0 to 176 (°F)
P
Sut 0
0 to 500
P
cth 1
1 to 30
P
ctc 1
1 to 30
P
S
– –
0
1 to 420 (°C)
34 to 788 (°F)
P
H2O yES
yES/no
SEt
Fun
∆ ∇
3 s
+
P
Adr
1
0 to 99
P