7.4 Offset Level “SEt OFS”
Offset compensation (deviations from measuring lines,
measurement errors from sensors, etc.)
The desired position can be reached by pressing the “
key or “” key. To move backwards: press the “P” key for
a maximum of 2 s.
To return to the operating level with display of the set and
actual values from any desired display, press the “P” key for
3 s.
Offset sensor Sn1 (°C/°F).
Offset sensor Sn2 (°C/°F).
Offset sensor Sn3 (°C/°F). Appears only when sensor is
present.
Offset external set-value input (°C/°F). Appears only when
analog set-value input is present.
Offset recorder output 1 (°C/°F). Appears only when analog
recorder output is present.
Offset recorder output 2 (°C/°F). Appears only when analog
recorder output is present.
P
S1 0
± 20 (°C)
± 36 (°F)
P
S2 0
P
S3
0
P
SP 0
P
o1 0
P
o2 0
SEt
OFS
P
3 s
SEt SEL
SEt Fun
SEt ALA
3 s
P
+
± 20 (°C)
± 36 (°F)
± 20 (°C)
± 36 (°F)
± 20 (°C)
± 36 (°F)
± 20 (°C)
± 36 (°F)
± 20 (°C)
± 36 (°F)