nOTes On TROUBLesHOOTInG
Defect Cause Correction
Motor does not run - Tool/Battery contacts dirty Clean contacts when dry with non-conducting material
- Tool/Battery contacts damaged Send tool/battery to REHAU service center
- Battery not correctly locked into the tool Reinsert battery, pay attention to locking mechanism!
- Battery empty. Charge battery
- Battery faulty Send battery to REHAU service center or independently
give it to the recycling system
- Tool faulty Send tool to REHAU service center
Tool loses oil - Leak in oil tank or release valve Do not open the tool and do not remove or damage
the tool seal!
Send tool to REHAU service center
Tool does not reach - Leak in oil tank or release valve Do not open the tool and do not remove or damage
nal pressure the tool seal!
Send tool to REHAU service center
- Air in the hydraulic system Interrupt the compression process.
Hold reset knob under tension (see page 8/Item No. 2) and at the
same time continuously actuate the operating switch for about 10
seconds. If this does not correct the defect, the tool must be sent to
a REHAU service center.
- Tool faulty Send tool to REHAU service center
Battery does not charge - Charger not plugged in correctly Reinsert mains plug
- No power coming to socket Change socket
- Charger / Mains cable or plug damaged Send charger to REHAU service center
- Charger not ready Wait for green LED to ash
- Charger/Battery contacts dirty Clean contacts when dry with non-conducting material
- Charger/Battery contacts damaged Send charger/battery to REHAU service center
- Battery not locked correctly into the charger Reinsert battery, pay attention to locking mechanism!
If the defects cannot be remedied, send the tool to the REHAU service center or your dealer.