4
Start-up and Control
Switch Applicator on/off
MS 80: The device starts heating up as soon as it is
plugged in. Unplug it to turn it off.
MS 200: An illuminated on/off-switch indicates that the
applicator is switched on. Press the switch in order to
turn the applicator on or off.
Minor leaking while the applicator is warming up is due to
the hot-melt expanding in the nozzle and heating
chamber.
Adjusting the trigger (MS 200 only)
The adjustment of the trigger has influence on the lever
stroke and on how much glue can be dispensed at once.
A screwdriver can be used to turn the adjustable screw
on the left side of the applicators’ casing. The longer the
lever stroke, the more glue can be dispensed at once
and vice versa.
Wear protective gloves and safety
goggles whenever you work with the
applicator.
Avoid accidents by stumbling – Lay all
cables, hoses and conducts so that they
will not cause any risk of stumbling. For
this, install cable ducts and bridges.
Never direct the glue jet towards people!
The glue guns MS 80 and MS 200 are factory set to heat
up to approximately 200 °C when switched on.
MS 80: The temperature adjusting-screw can be found at
the back side of the applicator.
MS 200: The temperature adjusting-screw can be found
at the upper side of the applicator.
The temperature can be adjusted by turning the
adjusting-screw with a screw driver. The right-end stop is
the maximum temperature of 200 °C. Never turn the
screw with force! This will lead to damaging the
applicator. In order to lower the working temperature,
turn the adjusting screw counter clockwise.
Adjust Temperature
The glue applicator must only be used/applied for its
intended purpose. Please read the chapter „General
Safety Instructions“. If it is not used as intended, this may
cause bodily injuries or equipment damages. Disregard
of the safety instructions for the use of the applicator may
lead to serious burns.
Never lay the hot-melt applicator on its side.
Do not hold the nozzle top upward for too long.
Do not carry out overhead work.
Do not start working, before fitting a nozzle first.
Only replace nozzle when applicator is warm.
Only open the lid when the applicator has warmed up.
Do not overcharge the applicator; only fill it up to 1,5 cm
(~0.6 inch) under the rim.
Stop using the equipment, if the casing is damaged due
to shock, breakage or heavy wear.
All manuals and user guides at all-guides.com
all-guides.com