Wet Trimming:
Fault Possible cause Corrective action
Disc buildup. Water volume incor-
rectly adjusted at the
device.
Water supply not fully
open.
Spray tube plugged.
Inlet strainer plugged.
Inlet water pressure
too low.
Increase the water volume at the
trimmer (Fig. 9).
Open the water supply (Fig. 6).
Clean / decalcify the spray tube
(Sec. 5.3).
Remove the strainer with pliers
and clean / decalcify it.
The diameter of the inlet pipe is
too small risp. too many users
are connected to a small pipe
>>> Check if water pressure is at
least 1 bar (ask your plumber).
If necessary the water pressure
canarticiallyincreasedbyado-
mestic water work (electric pump
and pressure tank).
Ask your plumber.
Water sprays out
of the grinding
opening.
Too much water.
Water drainage imped-
ed.
Reduce the water volume at the
trimmer (Fig. 9).
Check/properly lay out drain tube
>>> slope (Fig. 3a + 3b).
No rinse water. Water connection not
properly established.
Spray tube soiled /
calcied.
Check the water connection
(Sec. 4.2 steps 4 - 6).
Clean/decalcify the spray tube
(Sec. 5.3).
Water is dripping
out between the
front door and
the housing.
Gipsum powder order
plaster grains on the
sealing surface.
Clean the sealing surface and
the sealing ring.