Parameters Number
Parameter Name Description
Set options
18
[18] 120min
(Default)
Setting range is from 5min to 900
min. , in 5min increments
Battery Equaliza-
tion Duration
19
[19] 240min
(Default)
Setting range is from 5min to 900
min, in 5min increments
Battery Equaliza-
tion Time-Delay
20
[20] 30 days
(Default)
Setting range is from 0 days to 30
days, in 1 day increments
Stops equalization charging
immediately
Starts Equalization charging
immediately
Equalization
interval
21
[21] ENA
[21] DIS
(Default)
Enable Equaliza-
tion Immediately
22
[22] DIS
Default
[22] ENA
Disables power-saving mode
Power-saving
Mode (ECO )
After a 5min delay from setting, the
inverter will enter a power saving
mode and detect the load size.
Loads greater than or equal to 50W,
will be powered by the solar inverter.
Otherwise, it will automatically stay in
a low detecting mode and not power
any loads under 50W
23
[23] DIS
[23] ENA
(Default)
Overload automatic restart is
disabled, and the unit will not turn
on the loads
Enables automatic restart if the load
shutdown output has occurred. The
unit attempts to restart the output
after 3 minutes and After 5 attempts
the unit will not longer resume to
turn on the loads
Overload
auto-start
No alarm
Enable alarm
25
26
[25] DIS
Buzzer alarm
[25] ENA
(Default)
No alarm prompts when the status
of the primary input source changes
[26] DIS
Mode Transition
Alarm
24
[24] DIS
Over-temperature automatic
re-start is disabled
The over-temperature protection is
activated and upon temperature
dropping, the unit automatically restarts
Overtemperature
auto-start
[24] ENA
(Default)