HOME 17
Charge High
Temperature
Protection
55℃ (51.2V
Circuit)
55℃ (51.2V
Circuit)
If the temperature is higher than the protection
temperature of 51.2V circuit for 5s, the protection will be
triggered, a pre-alarm message will be sent out
immediately, and the relay will be opened after a delay of
57℃ (12V
Circuit)
57℃ (12V
Circuit)
If the temperature is higher than the protection
temperature of 12V circuit for 3s, the protection will be
triggered, the switch of 12V circuit will be opened, and
the BMS power will be cut off immediately
Charge High
Temperature
Protection Recovery
50℃
51.2V Circuit
& 12V Circuit
50℃
51.2V Circuit
& 12V Circuit
If the temperature is lower than the protection recovery
temperature for 10s, the protection will be released and
the relay will be closed
If the battery is restarted or activated by PV charging
after the battery temperature drops below the protection
recovery temperature, the protection will be released,
the switch of 12V circuit will be closed, and the BMS will
restore power immediately
Discharge High
Temperature Warning
55℃ 55℃
If the temperature is higher than the warning temperature
for 10s, a warning will be triggered and a warning message
will be sent out immediately
Discharge High
Temperature Warning
Recovery
50℃ 50℃
If the temperature is lower than the warning recovery
temperature for 10s, the warning will be cleared
Discharge High
Temperature
Protection
60℃
51.2V Circuit
60℃
51.2V Circuit
If the temperature is higher than the protection
temperature of 51.2V circuit for 5s, the protection will be
triggered, a pre-alarm message will be sent out
immediately, and the relay will be opened after a delay of
62℃
12V Circuit
62℃
12V Circuit
If the temperature is higher than the protection
temperature of 12V circuit for 3s, the protection will be
triggered, the switch of 12V circuit will be opened, and
the BMS power will be cut off immediately
Discharge High
Temperature
Protection Recovery
55℃
51.2V Circuit
& 12V Circuit
55℃
51.2V Circuit
& 12V Circuit
If the temperature is lower than the protection recovery
temperature for 10s, the protection will be released and
the relay will be closed