HOME 8
51.2V 210Ah Lithium Battery
DO NOT over-charge or over-discharge the battery.
DO NOT discharge the battery at high temperatures above 140°F (60°C).
Battery Operational Parameters:
Operation Parameter
Charge Voltage
54.7V
Charge Cut-Off Voltage
58.4V
Discharge Cut-Off Voltage
41.6V (Firmware 137.3.1)
48V (Firmware 137.3.13)
Maximum Continuous Charge Current
105A
Maximum Continuous Discharge Current
200A
Charge Temperature Range
32°F~131°F / 0°C~55°C
Discharge Temperature Range
-4°F~140°F / -20°C~60°C
Storage Temperature Range
-4°F~95°F / -20°C~35°C
Operation Relative Humidity
5%~95%
Switch Operation:
o The battery can be turned on or off with the Self-Locking Switch and Self-Resetting Switch. For
the first time use, press down the Self-Locking Switch and long press the Self-Resetting Switch
for approximately 5-10 seconds to turn on the battery. There will be a series of clicks which are
completing self-checks on the battery. After the last click, the COM light should begin to flash
Orange and the Self-Resetting Switch can be released.
o Prior to long periods of storage, press the Self-Locking Switch again to turn off the battery.
When the battery is off, it has a low self-discharge rate and can hold the charge for a longer
period of time.
o If the battery is in protection mode, it can be restarted by long pressing the Self-Resetting
Switch for 3~5 seconds. After restarting, the battery will automatically run the self-check
program and release the protection mode if the recovery conditions have been reached.
Heating Function Operation
o The normal operation of the heating function requires a stable charge current greater than 8A.
The heating function will start operating automatically once the battery temperature drops
below 41°F (5°C) and stop operating automatically once the battery temperature rises above
50°F (10°C).
NOTE: The heating function will not be able to operate normally if the unit is not connected to
shore power, and the charger setting #28 is not greater than 5A. The solar array is not large
enough to preheat the battery.
C
harging Battery
During the standard charging process, the battery is first charged at a constant current via the 51.2V
Input/Output Terminals until the battery voltage reaches between 54.0V and 54.8V. The standard
charging process is considered complete when the charge current is less than 4.2A. However, leaving
the battery on float will continue to balance the battery cells and will not damage the battery. The
standard charging process normally takes 7 hours. The battery should be charged to 54.4V to
recalibrate the BMS which adjusts the SOC meter, and keeps it close to specifications. This should be
done periodically, or as needed. Setting number 9 on the inverter charger may be adjusted between
54.0V and 54.8V to accomplish your specific usage, and then to recalibrate the BMS when needed.
Safe charging requires battery temperatures within normal operating temperatures. If the heating
function is unable to work normally, battery temperatures above 32°F (0°C) is also required for the