EasyManua.ls Logo

Renogy Rover 60A - Displayed Parameters and Error Codes

Renogy Rover 60A
36 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
22
Screen
Displayed
Item/Parameter
Description
1
Chag State: Idle
Battery Voltage
Solar Panel Voltage
Charging Current
BatVol: 11.6V
PvVol: 0V
ChagCrt
LoadState: OFF Load in “ON” or “OFF”
Load current
Remaining battery capacity
Controller Temperature
LoadCrt: 0A
BatSoc: 100%
Dev Temp: 27°C
ChagPower: 0W Current Wattage
Load Wattage
The current day’s minimum battery voltage
The current day’s maximum battery voltage
LoadPower: 0W
MinBatVol: 12.5V
MaxBatVol: 13.5V
Fault: NULL
2
3
4
Charging State Indicators:
“Idle”, no charging
“MPPT”, MPPT charging
“EQU”, Equalization charging
“BST”, Boost charging
“FLT”, Float charging
“LIMIT”, current-limited charging
Controller Error Codes:
“BAT-LDV” over-discharge
“BAT-OVD” over-voltage
“BAT-UVW” under-voltage warning
“L-SHTCRT” load short-circuit
“L-OVRCRT” load over-current
“DEV-OVRTMP” internal over-temperature
“BAT-OVRTMP” battery over-temperature
“PV-OVP” solar panel over wattage
“PV-OC-OVD” solar panel over-voltage
“PV-REV” solar panel reverse-polarity
“BAT-REV” battery reverse-polarity

Related product manuals