XD100 Ventilation Disinfector
User Manual
This user manual provides the operation,regular maintenance
and safety information.
Read this user manual carefully before use and save it for future
reference.
The manual contains the warranty card. Please keep it for future
service use.
0598
This device complies with Part 15 of the FCC Rules.Operation is subject
to the follwing two conditions:
(1) This device may not cause harmful interference.
(2) This device must accept any interference received, including
interference that may cause undesired operation.
GuangDong EDA Technology Co., Ltd
Shuiwei Industrial Park,Tangjiao,Chashan Town,
Dongguan City,Guangdong Province,523393,China
:
Hotline : (86) 400-822-0138
Service Email info@rescomf.com
Rev 2.4
Lotus NL B.V.
Koningin Julianaplein 10, 1e Verd, 2595AA, The Hague, Netherlands.
E-mail: peter@lotusnl.com
Tel: +31644168999
EC REP
f
https://www.facebook.com/Rescomf

Questions and Answers

Summary

General Description

Environmental Notice and Cleaning

Advises users on cleaning, disinfecting the device, and lists important cleaning precautions.

Part List and Product Structure

Included Components

Lists the XD100 device, charger, USB cable, and user manual as part of the package.

Charging Guidance

Emphasizes using the correct charger and USB cable for charging specifications.

Device Components Overview

Identifies charging/working indicators, On/Off button, tubing port, and air inlet.

Technical Specifications and Guidance

Device Specifications

Details device dimensions, weight, battery, power, and operating conditions.

Connection Diagram

Illustrates how the device connects to a CPAP mask and tubing.

Electromagnetic Emissions

Declares compliance with CISPR 11 standards for electromagnetic emissions.

Electromagnetic Immunity

Declares compliance with IEC 61000 standards for electromagnetic immunity.

EMC Immunity and Environment

EMC Immunity Standards

Details immunity test levels for electrostatic, transient, surge, and power variations.

Electromagnetic Environment Conditions

Describes suitable flooring, humidity, and mains power quality for operation.

RF Emission Guidance

Conducted RF Emission Guidance

Provides guidance on conducted RF emissions and recommended separation distances.

Radiated RF Emission Guidance

Provides guidance on radiated RF emissions and field strength requirements.

Operation Instructions

Pre-Operation Checks

Pre-operation checks include cleaning accessories and using an airtight container.

Device Operation Steps

Explains how to turn on the device, the ozone cycle, and auto power-off.

Battery Charging Information

Charging Procedure and Indicator

Details how to charge the device using the USB cable and notes the charging indicator.

Low Battery Warning and Action

Explains low battery warning indicators and recommends charging promptly.

Symbols and Important Notes

Key Symbols Explained

Explains symbols for temperature limits, IP rating, EC representative, and WEEE.

Safety and Usage Precautions

Advises waiting for ozone dissipation, warns about ozone exposure, and mentions battery travel suitability.

Electromagnetic Compatibility (EMC)

EMC Warnings and Precautions

Warns against stacking the product with other devices and using non-compliant accessories.

EMC Compliance Notice

States compliance with IEC60601-1-2 and advises using provided EMC information.

Troubleshooting and Warranty

Troubleshooting Power and Charging

Solutions for device not turning on, charging light issues, or not working after charging.

Troubleshooting Operational Issues

Solutions for machine stopping, no ozone, or cycle not completing.

Warranty Card Details

Fields for customer name, address, serial number, distributor, and repair date.

Warranty Service Information

Instructions to retain the warranty card and sales receipt for service.

Overview

The RESCOMF XD100 Ventilation Disinfector is a device designed for the sanitization of CPAP accessories, such as masks and tubing. It utilizes controlled ozone to kill 99.9% of germs and bacteria, including Escherichia coli (8099), Staphylococcus aureus (ATCC 6538), and Candida albicans (ATCC 10231). The sanitization process is entirely dry, requiring no water, soap, or chemical cleaning.

Function Description:

The device operates on a 35-minute sanitization cycle. This cycle includes 30 minutes of ozone streaming, followed by 5 minutes of fresh air circulation to remove residual ozone. The manufacturer states that repeating the cycle is not necessary. To initiate the process, the user presses and holds the On/Off button for 3 seconds. A single beep and a green light indicate that ozone streaming has begun. After the 35-minute cycle, the device automatically powers off, signaled by five beeps and the green light turning off. Users are advised to wait at least an hour after the cycle before using their CPAP/Bi-Level accessories to allow any remaining ozone odor to dissipate. The device can be manually turned off during the sanitization process by pressing and holding the On/Off button for 3 seconds, which will result in a long beep and the green light turning off.

For optimal disinfection, it is recommended to place CPAP/BiPAP accessories and the RESCOMF Ventilation Disinfector inside an airtight container with dimensions equal to or smaller than 350x220x140mm (13.78” x 8.66” x 5.57”). Before sanitization, any visible residue on the CPAP/BiPAP mask or nasal pillow should be wiped clean with a cleansing wipe or damp cloth, and accessories should be disconnected from the CPAP/BiPAP machine.

Important Technical Specifications:

  • Size: 117x68x50 (mm)
  • Weight: 205g
  • Battery: Rechargeable Lithium-ion battery 2000mAh
  • Power: 4W
  • Transportation and storage conditions:
    • Environmental temperature: -20℃~55℃
    • Relative humidity: ≤93%
    • Pressure: 80~106kPa
  • Operating conditions:
    • Environmental temperature: -5°C~45°C
    • Relative humidity: ≤85%
    • Pressure: 80~106kPa
  • Ingress Protection (IP) rating: IP21
  • Product life expectancy: 5 years
  • Software release: V1.2
  • Charging: The device features a USB charging port. A red light indicates charging, and a green light signifies a full charge. The manufacturer recommends using the approved charger and USB cable to ensure electrical charging specifications are met. For best battery performance and life, it is advised to power off the device while charging. A full charge allows for at least 4 complete 35-minute working cycles.
  • Low Power Indication: When the battery is low, the main light will blink, and a long buzzer sound will be heard. The disinfector will continue to operate until the battery is completely discharged. Charging is recommended as soon as the light starts to blink to ensure the completion of the 35-minute cycle.

Usage Features:

The device is designed for ease of use with a single On/Off button and clear indicator lights for charging and operation. It offers a "care-free" sanitization process without the need for water or chemicals. The compact and lightweight design makes it portable. The 2000mAh rechargeable battery is equivalent to a mobile phone battery, making it acceptable for travel on most airlines.

Maintenance Features:

  • Cleaning: The outer surface of the instrument should be kept clean. A dry, soft cloth can be used for cleaning. If necessary, a soft cloth soaked in soap or water can be used, followed by immediate drying with a clean, dry cloth.
  • Disinfection: After cleaning, the equipment can be disinfected by wiping with medical alcohol and allowing it to air dry (or dry with a clean, dry soft cloth).
  • General Maintenance:
    • Users are advised to clean and disinfect the device every three months.
    • The battery should be recharged promptly when power is low and fully charged every 6 months when not in use to prolong its life.
    • The device should be stored in a dry room, protected from extreme moisture, heat, lint, dust, and direct sunlight when not in use.
    • It is recommended to sanitize the tubing and mask weekly.
    • The device is precision electronic equipment and must be handled carefully.
    • Repairs should only be undertaken by authorized qualified engineers from the manufacturer or distributor, using original RESCOMF parts, otherwise, the warranty will be void.
    • The equipment should be kept in its box after cleaning and disinfection for long-term storage, in a non-corrosive gas and ventilated room.
  • Safety Precautions:
    • Avoid strangulation due to cables and hoses.
    • Do not use the equipment if there are changes in operating system performance, damage, or worn/frayed components.
    • The equipment is not recommended for use with flammable anesthetic mixtures, during transit, with MRI equipment, or stacked with other equipment (if used this way, verify normal operation).
    • Do not use low-temperature steam, high-temperature disinfection, electronic beam, or other sterilization methods.
    • Do not use strong solvents like acetone.
    • Wear and tear materials (e.g., wire, silver polish) are prohibited.
    • Cleaning water temperature should be below 60 degrees Celsius.
    • Prevent any liquid from entering the shell or dipping any part of the instrument into liquid.
    • Do not pour liquid into the instrument during cleaning.
    • Ensure no cleaning fluid remains on the surface of the instrument.
    • Keep away from pets, pests, and children.

Electromagnetic Compatibility:

The XD100 Ventilation Disinfector complies with IEC60601-1-2 standards for electromagnetic compatibility. It is intended for use in typical commercial or hospital environments and domestic settings. Users should ensure it is used in such environments and be aware that portable and mobile RF communication devices may affect its performance. It is advised to avoid strong electromagnetic interference from sources like mobile phones and microwave ovens when using the disinfector. The product should not be placed close to or stacked with other devices unless normal operation can be verified in such a configuration.

Rescomf XD100 Specifications

General IconGeneral
BrandRescomf
ModelXD100
CategorySteriliser
LanguageEnglish