CLINICIANS MANUAL
Reorder number: 218021/5 01 07
RESMED CPAP S6

Questions and Answers

  • A
    Amanda MonroeAug 5, 2025
    Why does the treatment pressure seem low on my ResMed Medical Equipment?
    • K
      karen88Aug 5, 2025
      If the treatment pressure seems low on your ResMed Medical Equipment, it might be because the Delay Timer is in use; either wait for the pressure to build up or press the Start button. Other potential causes include dirty air filter strips (replace them), kinked or punctured air tubing (straighten or replace it), improperly connected air tubing (check and tighten both ends), missing plugs from mask ports (replace them), or changed pressure requirements for your treatment (adjust the pressures).
  • K
    Kim HernandezAug 13, 2025
    How to stop air leaking from my ResMed CPAP S6 mask?
    • E
      Eric Rodriguez IIIAug 13, 2025
      If air is leaking around your nose and eyes while using your ResMed Medical Equipment, make sure the nasal cushion is properly fitted onto the mask frame. Adjust the position of the mask and headgear straps, keeping in mind that tighter isn't always better. Check for and replace any missing plugs from the mask ports. If the nasal cushion is torn or distorted, replace it. You may also need to refit the entire mask system.
  • J
    Joanne RomeroAug 20, 2025
    What to do if SmartStart doesn't work on my ResMed Elite Medical Equipment?
    • K
      Kevin KingAug 20, 2025
      If SmartStart is enabled on your ResMed Elite Medical Equipment but the flow doesn't begin when you breathe into the mask, try taking a deeper breath in and out. Also, check for excessive leaks by adjusting the position of your mask and headgear. Ensure all plugs are in place on the mask ports, and the air tubing is firmly connected and not kinked or punctured. Verify that SmartStart is enabled. Finally, make sure you are using only the equipment recommended and supplied by ResMed.
  • S
    snortonAug 28, 2025
    Why won't my ResMed CPAP S6 Medical Equipment flow generator start?
    • R
      rfreemanAug 28, 2025
      If your ResMed Medical Equipment flow generator does not start, first ensure the power cord is properly connected at both ends. Next, check that the flow generator is switched on using the main switch at the rear of the unit. If it still doesn't start, try plugging it into another power outlet to rule out a faulty outlet.

Summary

Medical Information

Definition of Terms

Explains special terms and icons used in the manual for clarity and understanding.

Indicated Use

Specifies the intended medical use of the ResMed CPAP S6 system for treating adult obstructive sleep apnoea.

Contraindications

Lists medical conditions where CPAP therapy with this device is not recommended or is contraindicated.

Warnings

Precautions

Oxygen Use

Provides guidelines and warnings regarding the safe use of supplemental oxygen with the CPAP device.

Adverse Effects

Details potential side effects patients may experience during CPAP treatment, such as discomfort or irritation.

ResMed CPAP S6 Series

Setting Up the ResMed CPAP S6

Assembling the Device

Step-by-step instructions for correctly connecting and setting up the ResMed CPAP S6 flow generator and accessories.

Setting Up for Patient Use

Lightweight, Plus and Elite Models

Details specific setup functions and options available for different models of the ResMed CPAP S6 system.

Resetting the Hour Meter

Instructions on how to reset the device's hour meter, indicating device usage and compliance.

Setting the Treatment Pressure

Limiting the Delay Timer

Setting the Start Pressure

Elite Model

Setting the Real-Time Clock

Instructions for setting the device's internal clock for accurate compliance data logging.

Enabling SmartStart

Procedure to activate the automatic start/stop function based on patient breathing detected by the mask.

Using a Humidifier

Downloading Compliance Data

Information on how patient compliance data is recorded and can be downloaded for review.

Cleaning & Maintenance

Daily

Routine cleaning and maintenance tasks for the air tubing and mask to ensure proper function and hygiene.

Weekly

Weekly cleaning recommendations for the air tubing, mask, and headgear for ongoing device care.

Periodically

General care instructions for the device exterior, including cleaning and inspecting components for wear.

Replacing the Air Filter Strips

Guidance on when and how to replace the air filter strips in the CPAP flow generator.

Fitting the Filter

Replacing the Filter

Instructions on the correct procedure for fitting and replacing the air filter in the flow generator.

Servicing

Self-Testing (Plus and Elite Models)

Steps to perform a self-test to verify the correct operation of the flow generator's software and hardware.

Troubleshooting

Accessories;Spare Parts

Specifications

Performance

Details the operating pressure range and other performance characteristics of the ResMed CPAP S6.

Dimensions (H x W x D)

Provides the physical size specifications of the ResMed CPAP S6 flow generator.

Weight

States the weight of the ResMed CPAP S6 flow generator, noting potential variations.

Power Supply

Details the input voltage, frequency, and power consumption requirements for the device.

Housing Construction

Describes the material and manufacturing process used for the device's exterior housing.

Air Filter Strips

Specifies the material and composition of the air filter strips used in the device.

Environmental Ratings

Outlines the acceptable operating and storage temperature and humidity ranges for the device.

Air Tubing

IEC 601-1 Classifications

Lists the safety and electrical classifications according to the IEC 601-1 standard.

Glossary

Flow Characteristics

ResMed CPAP S6 Specifications

General IconGeneral
Device TypeCPAP
ModelS6
ManufacturerResMed
Modes of OperationCPAP
Altitude AdjustmentAutomatic
Pressure Range4 to 20 cm H2O
Ramp Time0-45 minutes
Power SupplyAC 100-240V, 50-60Hz

Related product manuals