Do you have a question about the ResMed AutoSet CS 2 and is the answer not in the manual?
Manufacturer | ResMed |
---|---|
Ramp | Yes |
Data Storage | SD card |
Compliance Monitoring | Yes |
Noise Level | 26 dBA |
Therapy Modes | CPAP |
Humidification | Integrated humidifier |
Electrical Requirements | 100-240V AC |
Altitude Range | Up to 8, 500 feet |
Defines terms, icons, and warnings for safe and effective device use.
Outlines user liability for injuries or damages from improper operation or maintenance.
Details intended use and lists conditions where the device may be contraindicated.
Crucial safety information, including warnings about life support and device limitations.
Highlights potential side effects and when to report unusual symptoms to a physician.
Guidelines for initiating therapy, including blood pressure checks and mask fitting.
Step-by-step instructions for commencing and ending a treatment session.
Procedure for attaching the air tubing and pressure sensor tube to the mask.
Details on adjusting therapy parameters like modes, pressures, and ramp settings.
How to manage alarm sound levels and specific alarm settings like LOW PS.
Accessing and understanding efficacy and usage data from therapy sessions.
Customizing features like Smart Data display, backlight, and language.
Settings for advanced parameters such as minimum and maximum pressure support.
Accessing serial number, PCB, and software version for servicing purposes.
Displays mode, delivered pressure, and graphical pressure indication.
Shows leak, respiratory rate, apnoea/hypopnoea, and tidal volume.
Provides minute ventilation and target ventilation information.
Device for recording and transferring therapy data via SmartMedia card.
Details on compatible ResMed humidifiers for enhanced therapy comfort.
Information on using and replacing anti-bacterial filters for air quality.
Guidelines and warnings for adding supplemental oxygen to therapy.
Identification of the main parts of the AutoSet CS2 flow generator.
Guidance on choosing and setting up compatible masks for optimal therapy.
Step-by-step instructions for attaching and using ResMed humidifiers.
Instructions for running the AutoSet CS2 on DC power, including battery use.
Procedure for turning on the device and commencing therapy.
Methods for ending therapy, including automatic and manual stop functions.
Understanding the device's standby state and available actions.
Information displayed on the LCD screen during operation and menu navigation.
Functions of the Start/Stop and Up/Down keys for controlling therapy and menus.
Usage of Left, Right, and QuickView keys for menu access and data viewing.
How alarm LEDs function and how to mute audible alarms.
How to modify various therapy parameters via the control panel.
Selecting the correct mask type and performing the Air Circuit Learn function.
Configuring automatic stop, leak detection, and ramp time for therapy.
Viewing mask fit, average pressure, usage, and smart data.
Causes and solutions for low pressure and power failure alarms.
Troubleshooting high pressure and high leak conditions.
Addressing insufficient pressure support and flow blockage alarms.
Routine cleaning instructions for the device and accessories.
Guidelines for periodic checks, filter replacement, and cleaning precautions.
Information on fitting and replacing the hypo-allergenic air filter.