6
Reverso Pumps, Inc. www.reversopumps.com | contact@reversopumps.com | Ph: (954) 522-0882
Technical Specications
Flow Rate Approximately 210 GPH (795 LPH).
Actual flow rate may vary due to conditions of installation.
Operating Temperature 40 - 104°F (4-40°C)
Amp. Draw 3A@110V, 1.2A@220V
Circuit Breaker 10A@110V, 10A@220V
Service Space 4” on top and bottom, to facilitate changing filter elements and
draining water and particulate from the bowl
Pump Brass Gear stainless shaft- double lip seal
Maximum Suction Hose 32.8 ft / 10m with foot valve above liquid level
Maximum Delivery Hose 164 ft / 50m
Maximum Level Difference Between pump and suction: from 5 - 9.8 ft maximum / 1.5 to 3 m maximum.
Between pump and highest point of delivery: 23 ft / 7m maximum
Timer Digital PLC
Inlet 1/2” Male JIC
Outlet 1/2” Male JIC
Max Fluid Viscosity 29 CST
Filter Torque Values Bowl Retainer Ring 8 Nm (70 in-lbs)
Lid 8 Nm (70 in-lbs)
Plug 15 Nm (130 in-lbs)
Bleed Screw 4 Nm (35 in-lbs)
• The system has been developed to be used with diesel fuel only, DO NOT USE WITH GASOLINE.
• The system is designed to meet environmental standards for safe operation (NOT for use with uids that have a
ash point below 100°F (38°C), e. g.: Gasoline, alcohol,...)
Warning