EasyManuals Logo

Reverso FPS-210 Manual

Reverso FPS-210
16 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #6 background imageLoading...
Page #6 background image
6
Reverso Pumps, Inc. www.reversopumps.com | contact@reversopumps.com | Ph: (954) 522-0882
Technical Specications
Flow Rate Approximately 210 GPH (795 LPH).
Actual flow rate may vary due to conditions of installation.
Operating Temperature 40 - 104°F (4-40°C)
Amp. Draw 3A@110V, 1.2A@220V
Circuit Breaker 10A@110V, 10A@220V
Service Space 4” on top and bottom, to facilitate changing filter elements and
draining water and particulate from the bowl
Pump Brass Gear stainless shaft- double lip seal
Maximum Suction Hose 32.8 ft / 10m with foot valve above liquid level
Maximum Delivery Hose 164 ft / 50m
Maximum Level Difference Between pump and suction: from 5 - 9.8 ft maximum / 1.5 to 3 m maximum.
Between pump and highest point of delivery: 23 ft / 7m maximum
Timer Digital PLC
Inlet 1/2” Male JIC
Outlet 1/2” Male JIC
Max Fluid Viscosity 29 CST
Filter Torque Values Bowl Retainer Ring 8 Nm (70 in-lbs)
Lid 8 Nm (70 in-lbs)
Plug 15 Nm (130 in-lbs)
Bleed Screw 4 Nm (35 in-lbs)
The system has been developed to be used with diesel fuel only, DO NOT USE WITH GASOLINE.
The system is designed to meet environmental standards for safe operation (NOT for use with uids that have a
ash point below 100°F (38°C), e. g.: Gasoline, alcohol,...)
Warning

Other manuals for Reverso FPS-210

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Reverso FPS-210 and is the answer not in the manual?

Reverso FPS-210 Specifications

General IconGeneral
BrandReverso
ModelFPS-210
CategoryControl Unit
LanguageEnglish

Related product manuals