HRV / ERV INSTALLATION AND
OPERATION INSTRUCTIONS
Field Balancing Ports
RHRV-C100PECM
Polypropylene Core
RERV-C100ECM
Enthalpy Core

Questions and Answers

  • T
    Trevor ThompsonAug 13, 2025
    How to troubleshoot low air flow in Reversomatic RERV-C100ECM?
    • M
      Mrs. Amy MooreAug 13, 2025
      Low air flow in your Reversomatic Industrial Equipment can stem from several causes. The filter might be clogged, so try removing and cleaning it. Similarly, the core could be obstructed, requiring removal and cleaning. Check for any blockages in the exterior fresh air supply and clear them. Ductwork restrictions can also reduce airflow, so inspect the duct installation. Finally, a low power supply (low voltage) could be the culprit; in this case, immediately switch off the unit and call an electrician to check the voltage.
  • K
    kkennedyAug 16, 2025
    What to do if LEDs on Reversomatic RERV-C100ECM flash 0.5 sec On/0.5 sec Off/0.5 sec On then 2 sec Off?
    • J
      Jessica RobertsAug 16, 2025
      If the LEDs on your Reversomatic Industrial Equipment's Main Control board and remote Timer Switch are flashing 0.5 sec On/0.5 sec Off/0.5 sec On then 2 sec Off, repeatedly, it usually indicates an exhaust fan issue. This could be due to an open circuit, a burned motor, or an overheated fan, in which case you should replace the motor. Another possibility is a jammed or over-current exhaust fan, which also necessitates fan replacement. Additionally, check the backdraft damper for any obstructions, ensuring no screw interferes with its function.
  • D
    Deborah RayAug 20, 2025
    What does it mean if LEDs on Reversomatic RERV-C100ECM flash 0.5 sec On/0.5 sec Off seven times then 2 seconds Off?
    • S
      Sarah LevyAug 20, 2025
      If the LEDs on the Main Control board and remote Timer Switch of your Reversomatic Industrial Equipment flash in a specific pattern (0.5 sec On/0.5 sec Off seven times, then 2 seconds Off, repeating), it often points to a supply fan issue. This could be due to an open circuit, a burned motor, or an overheated fan, requiring you to replace the motor. Also, check the back-draft damper to ensure it's free from obstructions and that no screws are interfering with its function. Another cause may be a jammed or over-current supply fan, which means you will need to replace the fan.
  • E
    Ebony OlsonAug 25, 2025
    Why am I sensing cold air from the supply of my Reversomatic RERV-C100ECM?
    • A
      Ashley ClarkAug 25, 2025
      If you're sensing cold air from the supply of your Reversomatic Industrial Equipment, it could be due to a blocked exhaust hood outside the house; remove the blockage and clean the hood. Also, the HRV/ERV airflow might be improperly balanced, requiring a professional balancer or contractor to balance the unit. The placement of furniture or closed doors restricting air movement in the home can also cause this issue, consider installing a duct heater.
  • K
    Kimberly MurrayAug 27, 2025
    What causes Reversomatic Industrial Equipment to not defrost properly?
    • C
      Courtney CurryAug 28, 2025
      If your Reversomatic Industrial Equipment isn't defrosting properly, the fresh air duct might be frozen; check it and remove any ice. In addition, the HRV/ERV airflow may be improperly balanced, so have a professional balancer or contractor balance the unit. Finally, the temperature sensor could be defective, requiring replacement.
  • D
    Dr. Nicholas FigueroaAug 31, 2025
    What does it mean when all 3 LEDs of timer switch blink on Reversomatic RERV-C100ECM?
    • N
      Natalie MontesAug 31, 2025
      If all 3 LEDs of the timer switch on your Reversomatic Industrial Equipment are blinking, it may be due to the control board reporting an error. Also, it could be caused by lost communication with the main control board, so check all wire connections on both the timer switch and the main control board.
  • C
    campbelltammySep 4, 2025
    What to do if the timer switch light doesn't stay on in Reversomatic RERV-C100ECM Industrial Equipment?
    • K
      Kelli KingSep 4, 2025
      If the light on your Reversomatic Industrial Equipment's timer switch (20/40/60 minute / intermittent Switch) doesn't stay on, check the connection, as it may be loose. If the connection is secure, the switch itself may be defective and require replacement. You can also try resetting the main controller.
  • J
    Jeffery StantonSep 8, 2025
    What does it mean if LEDs on Reversomatic RERV-C100ECM flash 0.5 sec On/0.5 sec Off eight times then 2 seconds Off?
    • R
      Ryan GarzaSep 8, 2025
      If the LEDs on the Main Control board and the remote wall mount Timer Switch of your Reversomatic Industrial Equipment flash in a specific pattern (0.5 sec On/0.5 sec Off eight times, then 2 seconds Off, repeating), it indicates a temperature sensor failure. In this case, you should replace the temperature sensor.

Summary

IMPORTANT SAFETY INSTRUCTIONS

WARNING

TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK OR INJURY, OBSERVE THE FOLLOWING:

Wiring Diagram

Superior ECM Wiring

Detailed wiring diagrams for the unit's electrical connections and components.

Wiring Diagram (contd)

Air Flow Balancing

Balancing Procedure

Steps to ensure balanced airflow for optimal unit performance.

Pitot Tube Airflow Balancing

Method for field balancing airflow using a pitot tube and gauge.

Air Flow Balancing (contd)

Maintenance (contd)

Troubleshooting

Troubleshooting (contd)