H7387_d
RE 30146, edition: 2013-10, Bosch Rexroth AG
Digital control electronics
for electro-hydraulic
injection molding machines
Contents
Features 1
Ordering code 2
Functional description: Overview 3
Functional description: Injection control 3
Block diagram 6
Technical data 7
Pin assignment of the male multipoint connector 8
Pin assignment of the D-Sub socket on the front panel 8
Dimensions 9
Project planning / maintenance instructions /
additional information 10
Component series 2X
RE 30146 
Edition: 2013-10
Replaces: 08.07
Type VT-HACD-DPQ
Features
Actual value recording via SSI encoder, incremental or
analog position measurement system possible
Free confi guration of the valve control spool
Control loop adjustment
Jog mode controlled
Separate menus for injection, holding pressure and
back pressure
Pressure transition via:
Position
Internal mold pressure
Hydraulic pressure via position
Discrete input
Enable input and OK output
±10 V reference voltage output
Front display with keys to display and change param-
eters as well as for diagnosis purposes
RS232 serial interface
Up to 32 controller cards can be interconnected for
parameterization and diagnosis via the local bus
Internal or analog profi le
I/O confi guration
Question and Answer IconNeed help?

Do you have a question about the REXROTH VT-HACD-DPQ Series and is the answer not in the manual?

REXROTH VT-HACD-DPQ Series Specifications

General IconGeneral
CategoryController
SeriesVT-HACD-DPQ
ManufacturerREXROTH
Supply Voltage24 V DC
Input Voltage24 V DC
Protection ClassIP20
InterfaceDigital
Operating Temperature0°C to 50°C
Storage Temperature70 °C

Summary

Features Overview

Ordering Code

Core Product Identification

Identifies the controller card, axis, series, and basic unit.

Functional Description: Injection Control

Injection Profile Control

Details the velocity profile control with up to 10 steps and pressure limits.

Transition to Holding Pressure

Explains criteria and process for transitioning to holding pressure.

Holding Pressure Phase

Describes the holding pressure phase with up to five steps and superimposed velocity control.

Technical Data

Electrical Specifications

Details operating voltage, current consumption, digital I/O, and analog input/output specs.

Pin Assignment

Male Multipoint Connector

Detailed pin assignment for the 64-pole male multipoint connector.