7.2. Harrison address conversion to switch settings
The address used is converted to the address selected in the Harrison curtain motor using the
table below.
switch 1 2 3 4 5 6 7 8
H H H H X X X X
A 0 1 1 0 1 0 0 0 0
B 0 1 1 1 2 0 0 0 1
C 0 1 0 0 3 0 0 1 0
D 0 1 0 1 4 0 0 1 1
E 1 0 0 0 5 0 1 0 0
F 1 0 0 1 6 0 1 0 1
G 1 0 1 0 7 0 1 1 0
H 1 0 1 1 8 0 1 1 1
I 1 1 1 0 9 1 0 0 0
J 1 1 1 1 10 1 0 0 1
K 1 1 0 0 11 1 0 1 0
L 1 1 0 1 12 1 0 1 1
M 0 0 0 0 13 1 1 0 0
N 0 0 0 1 14 1 1 0 1
O 0 0 1 0 15 1 1 1 0
P 0 0 1 1 16 1 1 1 1
H H H H = House code
X X X X = device code
Switch position in the motor:
Up = 1
Middle = not used!!!!
Down = 0
Examples:
If you assign the address E7 (1000 0110) to the curtain motor then set the switches to: 1=up,
2=down, 3=down, 4=down, 5=down, 6=up, 7=up, 8=down
If you assign the address A2 (0110 0001) to the curtain motor then set the switches to: 1=down,
2=up, 3=up, 4=down, 5=down, 6=down, 7=down, 8=up