TM049 27L Continuous Flow Service Instructions
REV AL Issued April 2019
This document is stored and maintained electronically by Rheem Technical Support. All printed copies are deemed “uncontrolled”.
59
Fault Finding Test 25
Test 25
Conduct test with water & gas isolated
Ensure power is off whilst confirming the fan wiring is securely in place.
Reapply power to water heater. Once initialisation period has expired (~2mins) enter
heater maintenance mode and display 6Y (fan speed in RPM). Lock this code by turning
Dip switch 2 on DIP1 set of switches ‘ON’.
Depress and hold MIN (SW1) button to initiate low fire fan operation and use table below
to confirm fan speed is correct.
Depress and hold MAX (SW2) button to initiate high fire fan operation and use table below
to confirm fan speed is correct.
Fan speeds are to be as follows:
5 Star Models
Sea Level
1000 2000 Metres
2001 3000 Metres
Model
MIN
MAX
MIN
MAX
MIN
MAX
27L Ext NG
2700
6700
2900
7100
3100
7500
27L Int NG
2700
6050
2819
6250
2984
6650
27L Ext Prop
2800
6600
3000
7000
3200
7400
27L Int Prop
2630
6400
2768
6800
2932
7300
6 Star Models
Sea Level
1000 2000 Metres
2001 3000 Metres
Model
MIN
MAX
MIN
MAX
MIN
MAX
27L Ext NG
3200
6400
3400
6800
3600
7200
27L Int NG
3000
6800
3200
7250
3350
7600
27L Ext Prop
3200
6650
3400
7050
3600
7450
27L Int Prop
3250
6750
3450
7150
3650
7550