Field Conversions
SEE CRITICAL HOSE CLAMP LOCATION NOTE IN
THE GENERAL CONVERSION INSTRUCTIONS.
5
CUT
IF REQ’D.
INSTALL
HOSE E
HOSE F
CUT
INSTALL
CUT
INSTALL
ROTATE
UNIT 90°
5a - ROTATE UNIT 90
5b - CUT 1/4" VENT HOSE TO FIT (APPROX. 5-1/2") AND INSTALL AS SHOWN.
5c - CUT HOSE E AT LINE 1- INSTALL
NOTE: MAKE SURE CUT IS STRAIGHT AND SQUARE
5d - CUT HOSE F ON LINE CORRESPONDING TO UNIT WIDTH AND INSTALL
NOTE: 17.5": LINE 1, 21": LINE 2, 24.5": DO NOT CUT
NOTE:
USE SOAPY WATER TO FACILITATE EASY
HOSE AND TUBE ASSEMBLY
1/4” TUBE CUT
TO FIT (APPROX. 4”)
5a
5b
5c 5d
4
4a - REMOVE METAL BRACKET AND THE Ø.403 DRAIN
PLUG- DISCARD.
4b - REMOVE HOSE “A” - DISCARD
4c - INSTALL Ø .559" CONDENSATE DRAIN PLUG AND
CONDENSATE TRAP GASKET AS SHOWN.
4d - INSTALL CONDENSATE TRAP. MAKE SURE THE
CHANNEL AT THE LOCATION SHOWN IN THE “IMPORTANT
SECTION” ENGAGES THE EDGE OF THE JACKET AT THE
LOCATION SPECIFIED.
4e - SECURE USING (3) SCREWS.
NOTE: TO PREVENT DAMAGE TO THE TRAP, THE INSTALLER MAY ELECT TO
INSTALL IT DURING A LATER STEP. (AFTER THE UNIT IS ROTATED)
DISCARD
HOSE A
DISCARD
INSTALL
4a
4b
4c
4d
R
ECTANGLE PLUG
DISCARD
DRILL (3)
Ø1/8" HOLES
3a - REMOVE RECTANGLE FLUSH MOUNT PLUG
FROM JACKET SIDE-DISCARD
3
b - PRE-DRILL (3) Ø 1/8" HOLES AS SHOWN
FOR CONDENSATE TRAP
3a
3b
3
NOTE: REMAINING STEPS SHOWN WITH FURNACE IN HORIZONTAL RIGHT ORIENTATION
ST-A1194-32-01
!! IMPORTANT !!
THIS CHANNEL
MUST ENGAGE
JACKET AT THIS
EDGE TO AVOID
AIR LEAKS TO
THE BURNER
VESTIBULE!
CONDENSATE TRAP
INFORMATION
TRAP
JACKET
I
NSTALL CONDENSATE TRAP
INSTALL CONDENSATE TRAP