INSTALLATION INSTRUCTIONS
General
Every vent or air intake pipe penetration of a floor or
ceiling should be sealed.
Failure to install and properly vent the water heater
to the outdoors as outlined on pages 34 through 46
can result in unsafe operation.
Long hot water lines should be insulated to conserve
water and energy.
The water heater and water lines should be protected
from exposure to freezing temperatures.
Minimum water heater clearances from combustible
and noncombustible construction are as follows:
– 1/2 in. (1.3 cm) for sides
– 0 in. (0 cm) for rear with support bracket(s)
– 12 in. (30 cm) from the bottom, top, and front
12" min.
(300 mm)
12" min.
(300 mm)
1/2" min.
(13 mm)
12" min.
(300 mm)
0"
(0 mm)
0" min.
(0 mm)
Sealed
D o not install the water heater in
areas prohibited by CAN/CSA B149.1
Natural Gas and Propane Installation
Code.
D o not install the water heater where
it is subject to vibrations.
D o not install the water heater in a
recreational vehicle, mobile home,
boat, or other watercraft.
D o not install the water heater near
vents for heating and cooling unless
a minimum clearance of 4 ft (1.2 m) is
maintained.