EasyManua.ls Logo

Rheem CRTGH-95X Series - Insulation Blankets

Rheem CRTGH-95X Series
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
61
INSTALLATION INSTRUCTIONS
Insulation Blankets
In general, insulation blankets for external use on
gas water heaters are not necessary. The purpose of
an insulation blanket is to reduce the standby heat
loss from the water heater’s storage tank. Since these
water heaters do not store water, they eliminate the
need for the insulation blanket.
The manufacturer’s warranty does not cover any
damage or defect caused by insulation, insulation
attachment, or use of any type of energy-saving or
other unapproved devices (unless authorized by the
manufacturer). The use of unauthorized energy-saving
devices can result in death, personal injury, and/or
property damage. The manufacturer disclaims any
responsibility for such loss or injury resulting from the
use of such unauthorized devices.
Installation Precautions
Follow all installation instructions covered in this
manual.
Check the inlet gas pressure to make sure it is within
the range specified on the rating plate.
Make sure there is adequate air for combustion and
ventilation as described on pages 37–38 or page 44
in this manual.
Maintain proper clearances to combustibles and
noncombustibles as specified on the rating plate.
Make sure the venting system complies with local
codes, National Fuel Gas Codes (ANSI Z223.1/NFPA
54) or CAN/CSA B149.1, and the guidelines found on
pages 34 through 46 in this manual.
Make sure the heater and remote control are
properly fastened to their mounting surfaces.
Make sure the heater and remote control are wired
in accordance with all regulations and codes without
any exposed connections.
Contact the local gas company to make sure the gas
meter and gas piping are adequately sized.
Use only Teflon tape on all male water line
connections and fittings.
D o not block or restrict any air intake openings.
D o not remove the front cover unless absolutely
necessary. This should only be done by a qualified
service technician.
D o not install this product where standing water may
occur.
D o not use pipe dope on water line connections and
fittings.
D o not use teflon tape on gas line connections and
fittings in US.
Electrical