EasyManuals Logo

Rheem CRTGH-95X Series User Manual

Rheem CRTGH-95X Series
72 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #68 background imageLoading...
Page #68 background image
68
Start/Adjust
INSTALLATION INSTRUCTIONS
Minimum Temperature Adjustment by
the Main Remote Control (UMC–117,
USC1–117, and USC2–117)
Residential water heater temperatures can be adjusted
down to 85°F (29°C), when required.
To change the temperature settings down to
85°F (29°C):
Turn on the remote control.
Turn off the gas and water to the water heater by
closing the shut-off valves.
Press the DOWN adjustment button repeatedly until
100°F (38°C) shows in the LED display.
NOTICE: LED display only shows °F.
Press the DOWN adjustment button 3 times within 5
seconds. The display will show “85.”
Turn on the gas and water to the water heater by
opening the shut-off valves.
NOTICE: The maximum flow rate at 85°F (29°C)
is 1.3 gpm (5.0 L/m).
When the water heater is installed above 3,280 ft.
(1,000 m), the settings on the DIP switch located on
the printed circuit board (PCB) need to be changed. If
these settings are not changed, the water heater may
not function properly.
NOTICE: If the water heater is installed under
3,280 ft. (1,000 m) altitude, no adjustments are
required.
Verify the altitude that the water heater is installed.
Turn off the gas and water to the water heater by
closing the shut-off valves.
1
2
4
5
High-Altitude DIP Switch Adjustments
1
3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Rheem CRTGH-95X Series and is the answer not in the manual?

Rheem CRTGH-95X Series Specifications

General IconGeneral
CategoryResidential
CondensingYes
Activation Flow Rate0.4 GPM
TypeTankless
Fuel TypeNatural Gas
Warranty12-Year Heat Exchanger
Water Connection3/4" NPT
Voltage120V
Ignition TypeElectronic