Typical Installation Drawing.
NOTES:
1.) The gas supply piping must be adequately
supported and aligned to minimize loads (forc-
es) on the water heater’s gas valve and burner
system.
2.) Refer to local codes for installation guidelines
for the Thermal Expansion Tank (if required).
A manual valve, union, and
a sediment trap shall be
provided in front of the gas
valve. All gas piping must
conform to local codes and/
or the National Fuel Gas Code
ANSI 223.1/NFPA 54 or CSA
B149.1. Figure 6 shows the
installation of a sediment trap
to the gas piping on the water
heater
Installation
Regulated Gas Supply Line
Main Gas Shutoff Valve
Union
Tee
Sediment Trap
Pipe Cap
Figure: 5
Figure: 6