Installation Check List
A. Water Heater Location
Close to area of vent.
Indoors and protected from freezing temperatures.
Proper clearance from combustible surfaces ob-
served and water heater not installed on carpeted
floor.
Air supply free of corrosive elements and flam
mable vapors.
Provisions made to protect area from water dam-
age.
Sufficient room to service heater.
B. Water Supply
Water heater completely filled with water.
Water heater and piping air vented.
Water connections tight and free of leaks.
C. Gas Supply
Gas line equipped with shut-off valve, union, and
sediment trap/drip leg.
Approved pipe joint compound used.
Soap and water solution used to check all con-
nections and fittings for possible gas leak.
Gas Company inspected installation (if required).
D. Relief Valve
Discharge line run to open drain.
Discharge line protected from freezing.
E. Venting
All pipe connections are secure (at blower, vent
terminals and for each pipe joint connection)
Vent terminals mounted properly and in correct
location.
F. Condensate
Condensation trap installed and primed.