Wiring and Schematic Diagrams
Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation VERIFY PROPER
OPERATION AFTER SERVICING!
CAUTION
!
J13
1K
J16
BK
BK
PK
PK
BK
BK
YL
YL
BR
BR
RD
RD
J16
J5
J5
J5
J5
J5
J5
J5
J5
J5
J14
J1
S4
ON
OFF
ARGUS LINE/
PC CONNECTION
ARGUS LINE
BUS POWER
PROGRAMMING HEADER
PROGRAMMING JUMPER
SAFETY LIMIT
(ECO)
FLUE
BLOCKED INTAKE/EXHAUST
SWITCHES
AIR FLOW
PROVING SWITCH
AIR FLOW
PROVING SWITCH
TEMPERATURE
PROBE
EXTERNAL
DISPLAY
IONIZATION
IGNITION
SPARK
RETURN
IGNITER CABLE
BURNER
BLOWER
JUMPER
GAS VALVE
120VAC 60Hz
ON
OFF
SAFETY LIMIT
(ECO)
FLUE
BLOCKED INTAKE/
EXHAUST SWITCHES
TEMPERATURE
PROBE
EXTERNAL
DISPLAY
IONIZATION
IGNITION
SPARK
RETURN
L N GN
IGNITER CABLE
BURNER
BLOWER
JUMPER
GAS VALVE
120VAC 60Hz
J18
J18 J2
J2
J2
J13
J13
J13
J13
J13
J9
J9
J9
J12
T2
YL
OR
GN
GN
GN
BK
W
BL
YL
YL
BK
BK
W
W
GN
GN
GN
LN
1K
J5
CONNECTION DIAGRAM
IMPORTANT
AC POLARITY
L - LINE N - NEUTRAL GN - GROUND
SCHEMATIC
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THIS APPLIANCE MUST BE
REPLACED, IT MUST BE REPLACED WITH 18 GA., 600V, 105°C WIRE OR ITS
EQUIVALENT.